Belden 27150A Cable 8 AWG 3 Conductors Stage Lighting 600V Type TC Bare Copper Cable

Belden 27150A Cable 8 AWG 3 Conductors Stage Lighting 600V Type TC Bare Copper Cable

Select gauge from drop-down menu for prices:

Belden 27150A Cable 8 AWG 3 Conductors Stage Lighting 600V Type TC Bare Copper Cable
Belden 27150A Cable 8 AWG 3 Conductors Stage Lighting 600V Type TC Bare Copper Cable

Description:
• 8 AWG multi-conductor stranded (7x16) bare copper conductors, 10 AWG bare copper ground wire, PVC/Nylon insulation, PVC jacket.

Insulation:
• Material: PVC/Nylon - Polyvinyl Chloride/Nylon

Ground Wire:
• Ground Wire (Y/N): Y
• Ground Wire AWG: 10
• Ground Wire Stranding: 7x18
• Ground Wire Conductor Material: BC - Bare Copper

Outer Jacket:
• Material:PVC - Polyvinyl Chloride
• Nom. Wall Thickness (in.): 0.063

Mechnical Characteristics (Overall):
• Wet Temperature Range: -30°C To +75°C
• Dry Temperature Range: -30°C To +90°C
• Bulk Cable Weight: 286 lbs/1000 ft.
• Max. Recommended Pulling Tension: 576 lbs.
• Min. Bend Radius/Minor Axis: 6 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards & Environmental Programs:
• NEC/(UL) Specification: TC, THHN/THWN Singles
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire & Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: S-95-658, S-61-402

Electrical Characteristics (Overall):
• Nom. Conductor DCR @ 20°C (Ohm/1000 ft): 0.064 
• Max.Operating Voltage - UL: 600 V RMS
• Max. Recommended Current: 55 Amps per conductor @ 25°C

Flame Test:
• UL Flame Test: UL1685 UL Loading 
• C(UL) Flame Test: FT4 

Suitability:
• Suitability - Burial: Yes
• Sunlight Resistance: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): No

Benefits And Features:
• Belden offers more than 25 variations for DMX / RS-485 applications
• Many of Belden's lighting cables are designed for industrial standards, and their rugged and resistant cable options are suitable for many indoor and outdoor lighting challenges

technical specification:
awg 8
# pair -
stranding 7x16
no. of conductors 3
conductor material Bare Copper
dia. (in.) -
outer shield - type -
outer shield - material Unshielded
overall cable - nominal dia. (in.) 0.595
belden cable part number 27150A

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question