Belden 1800B Cable 24 AWG 1 Pair Stage Lighting Non Plenum PVC Jacket Cable

Belden 1800B Cable 24 AWG 1 Pair Stage Lighting Non Plenum PVC Jacket Cable

Select gauge from drop-down menu for prices:

Belden 1800B Cable 24 AWG 1 Pair Stage Lighting Non Plenum PVC Jacket Cable

Regular price $1.41 $0.94 Sale /per Foot

Belden 1800B Cable 24 AWG 1 Pair Stage Lighting Non Plenum PVC Jacket Cable

Description:
• 24 AWG stranded (7x32) tinned copper conductors, Datalene® insulation, twisted pairs, overall Beldfoil® shield (100% coverage), 24 AWG drain wire, PVC jacket.

Insulation:
• Trade Name: Datalene®
• Material: FHDPE - Foam High Density Polyethylene
• Wall Thickness (in.): 0.024

Outer Shield Drain Wire AWG:
• AWG: 24
• Stranding: 7x32
• Material: Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride

Mechnical Characteristics (Overall):
• Operating Temperature Range: -30°C To +60°C
• Bulk Cable Weight: 16 lbs/1000 ft.
• Max. Recommended Pulling Tension: 16.500 lbs.
• Min. Bend Radius/Minor Axis: 2 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards & Environmental Programs:
• NEC/(UL) Specification: CMR
• CEC/C(UL) Specification: CMR
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire & Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: AES/EBU

Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 110
• Nom. Inducatance (μH/ft): 0.018 
• Nom. Capacitance Conductor to Conductor (pF/ft): 12
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/ft): 26
• Nominal Velocity of Propagation VP (%): 76
• Nom. Conductor DCR @ 20°C (Ohm/1000 ft): 23.7
• Max.Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 2.75 Amps per conductor @ 25°C

Flame Test:
• UL Flame Test: UL1666 Vertical Shaft
• CSA Flame Test: FT4

Plenum/Non-Plenum:
• Plenum (Y/N): No
• Plenum Number: 1801B

Benefits And Features:
• Belden offers more than 25 variations for DMX / RS-485 applications
• Many of Belden's lighting cables are designed for industrial standards, and their rugged and resistant cable options are suitable for many indoor and outdoor lighting challenges

technical specification:
awg 24
# pair 1
stranding 7x32
no. of conductors 2
conductor material tinned copper
dia. (in.) 0.024
outer shield - type tape
outer shield - material aluminum foil-polyester tape
overall cable - nominal dia. (in.) 0.185
belden cable part number 1800B

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question