Belden 8772 20 AWG Audio Control and Instrumentation Non Plenum Cable

Belden 8772 20 AWG Audio Control and Instrumentation Non Plenum Cable

Select gauge from drop-down menu for prices:

Belden 8772 20 AWG Audio Control and Instrumentation Non Plenum Cable

Regular price $2.81 $1.87 Sale /per Foot

Description:
• 20 AWG stranded (7x28) tinned copper conductors, conductors cabled, polyethylene insulation, overall Beldfoil® shield (100% coverage), 20 AWG stranded tinned copper drain wire, PVC jacket.

Insulation:
• Material: PE - Polyethylene
• Wall Thickness (mm): 0.4318

Outer Shield Drain Wire AWG:
• AWG: 20
• Stranding: 7x28
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.8382

Overall Cabling Lay Length and Direction:
• Length (in.): 2.000
• Twists (twist/ft): 6.000 (Left Hand Direction)

Mechanical Charactertistics (Overall):
• Operating Temperature Range: -20°C To +60°C
• UL Temperature Rating: 60°C (UL AWM Style 2093)
• Bulk Cable Weight: 29 lbs/1000 ft.
• Max. Recommended Pulling Tension: 45 lbs.
• Min. Bend Radius/Minor Axis: 2.250 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CM
• NEC Articles: 800
• CEC/C(UL) Specification: CM
• AWM Specification: UL Style 2093 (300 V 60°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Capacitance Conductor to Conductor (pF/ft): 27
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/ft): 51
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 10.0
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 8.9
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 4 Amps/Conductor @ 25°C ambient (10C Temp. Rise)

Flame Test:
• UL Flame Test: UL1685 UL Loading
• CSA Flame Test: FT1

Suitability:
• Suitability - Indoor: Yes

awg # conductors stranding no.of
conductors
conductor
material
outer shield overall cable-
nominal
dia. (mm)
belden cable
part
number
type material
20 3 7x28 3 tinned copper tape aluminum foil-polyester tape 5.5372 8772