Product Details

Conductors: Flexible tinned copper 

Ground Check Conductor2: Flexible tinned copper with yellow polypropylene insulation 

Strand Shield: Semi-conducting layer

Insulation: 90°C ethylene-propylene rubber (EPR) 

Ground Wires: Flexible tinned copper 

Tape: Non-conducting 

Insulation Shielding: Tinned copper and color coded nylon braid 

Assembly: Taped core 

Jacket1: Thermoplastic Polyurethane (TPU) Jacket. Cable identification via permanent marking. 

Application: 
• Heavy duty portable power cable for use in circuits not exceeding 5,000 volts. Designed for applications such as shovels, dredges and drills. Recommended maximum continuous conductor temperature in 90°C. Suitable for shallow water submersion. 
• Heavy duty high voltage portable power cable for use in circuits not exceeding the rated voltage. These cables are used for heavy mobile equipment such as drag lines, shovels, dredges, and for power feeders.Recommended maximum continuous conductor temperature in 90°C. Suitable for shallow water submersion.(8kv,15kv,25kv)
• Cable carries “P-184-MSHA” marking indicating acceptance as flame resistant by the Pennsylvania Department of Environmental Protection and the Mine Safety and Health Administration. 
• Tiger® Brand Mining Cable meets or exceeds ICEA Standards S-75-381/NEMA WC-58, ASTM B-172 and B-33. 

Ratings & Approvals: 
• Mine Safety & Health Administration 184-MSHA. 
• Pennsylvania Department of Environmental Protection P-184. 
• Insulated Cable Engineers Association S-75-381/NEMA WC-58. Design standard for mining cables. 
• Canadian Standards Association C22.2 No. 96 File 82346, FT1, FT5, -50°C CSA Phase Color ID available on Type SHD-GC, SHD-BGC up to 25kV 
• Canadian Standards Association C22.2 No. 96 File 82346, FT1, FT5, -50°C CSA Phase Color ID available on MTO Type SHD-GC, SHD-BGC up to 25kV SHD-GC meets FT4 requirements(8kv,15kv,25kv)

power conductors ampacity* 40°c
ambient temp
amercable and
Tiger brand
part number
Action
size awg no .of wires
per conductor
36-514 type shd-gc 3/c tpu jacket 5000 volts
6 133 93 36-514-006 Request a Quote
4 259 122 36-514-004 Request a Quote
2 259 159 36-514-002 Request a Quote
1 259 184 36-514-001 Request a Quote
1/0 266 211 36-514-010 Request a Quote
2/0 323 243 36-514-020 Request a Quote
3/0 418 279 36-514-030 Request a Quote
4/0 532 321 36-514-040 Request a Quote
250 627 355 36-514-250 Request a Quote
350 888 435 36-514-350 Request a Quote
500 1221 536 36-514-500 Request a Quote
36-518 type shd-gc tpu jacket 8000 volts
4 259 122 36-518-004 Request a Quote
2 259 159 36-518-002 Request a Quote
1 259 184 36-518-001 Request a Quote
1/0 266 211 36-518-010 Request a Quote
2/0 323 243 36-518-020 Request a Quote
3/0 418 279 36-518-030 Request a Quote
4/0 532 321 36-518-040 Request a Quote
250 627 355 36-518-250 Request a Quote
350 888 435 36-518-350 Request a Quote
500 1221 536 36-518-500 Request a Quote
36-521 type shd-gc 3/c tpu jacket 15000 volts
2 259 164 36-521-002 Request a Quote
1 259 187 36-521-001 Request a Quote
1/0 266 215 36-521-010 Request a Quote
2/0 323 246 36-521-020 Request a Quote
3/0 418 283 36-521-030 Request a Quote
4/0 532 325 36-521-040 Request a Quote
250 627 359 36-521-250 Request a Quote
350 888 437 36-521-350 Request a Quote
500 1221 534 36-521-500 Request a Quote
36-526 type shd-gc 3/c tpu jacket 25000 volts
1 259 191 36-526-001 Request a Quote
1/0 266 218 36-526-010 Request a Quote
2/0 323 249 36-526-020 Request a Quote
3/0 418 286 36-526-030 Request a Quote
4/0 532 327 36-526-040 Request a Quote
250 627 360 36-526-250 Request a Quote
350 888 439 36-526-350 Request a Quote

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question