Amercable Tiger Brand 1 AWG Type SHD-GC 3/C TPU Jacket 5000 volts Cable 36-514-001

Amercable Tiger Brand 1 AWG Type SHD-GC 3/C TPU Jacket 5000 volts Cable 36-514-001

Select gauge from drop-down menu for prices:

Amercable Tiger Brand 1 AWG Type SHD-GC 3/C TPU Jacket 5000 volts Cable 36-514-001
Amercable Tiger Brand 1 AWG Type SHD-GC 3/C TPU Jacket 5000 volts Cable 36-514-001

Conductors: Flexible tinned copper 

Ground Check Conductor2: Flexible tinned copper with yellow polypropylene insulation 

Strand Shield: Semi-conducting layer

Insulation: 90°C ethylene-propylene rubber (EPR) 

Ground Wires: Flexible tinned copper 

Tape: Non-conducting 

Insulation Shielding: Tinned copper and color coded nylon braid 

Assembly: Taped core 

Jacket1: Thermoplastic Polyurethane (TPU) Jacket. Cable identification via permanent marking. 

Application: 
• Heavy duty portable power cable for use in circuits not exceeding 5,000 volts. Designed for applications such as shovels, dredges and drills. Recommended maximum continuous conductor temperature in 90°C. Suitable for shallow water submersion. 
• Heavy duty high voltage portable power cable for use in circuits not exceeding the rated voltage. These cables are used for heavy mobile equipment such as drag lines, shovels, dredges, and for power feeders.Recommended maximum continuous conductor temperature in 90°C. Suitable for shallow water submersion.(8kv,15kv,25kv) 
• Cable carries “P-184-MSHA” marking indicating acceptance as flame resistant by the Pennsylvania Department of Environmental Protection and the Mine Safety and Health Administration. 
• Tiger® Brand Mining Cable meets or exceeds ICEA Standards S-75-381/NEMA WC-58, ASTM B-172 and B-33. 

Ratings & Approvals: 
• Mine Safety & Health Administration 184-MSHA. 
• Pennsylvania Department of Environmental Protection P-184. 
• Insulated Cable Engineers Association S-75-381/NEMA WC-58. Design standard for mining cables. 
• Canadian Standards Association C22.2 No. 96 File 82346, FT1, FT5, -50°C CSA Phase Color ID available on Type SHD-GC, SHD-BGC up to 25kV 
• Canadian Standards Association C22.2 No. 96 File 82346, FT1, FT5, -50°C CSA Phase Color ID available on MTO Type SHD-GC, SHD-BGC up to 25kV SHD-GC meets FT4 requirements(8kv,15kv,25kv)

technical specification:
power conductors (size awg) 1
power conductors (no. of wires per conductor) 259
power conductors (insulation thickness mils) 110
grounding conductors (size awg) 5
grounding conductors (no. of wires per conductor) 133
jacket thickness mils 205
nominal outside dimensions in. 1.95
approx. weight lbs. per 1,000 ft. 2447
ampacity* 40°c ambient temp 184
amercable and tiger brand part number 36-514-001

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.