Superior Essex Cable EPR/CTS/PVC Power Type MV-105,3 Conductor 5kV-15kV Copper Conductors Cable

Superior Essex Cable EPR/CTS/PVC Power Type MV-105,3 Conductor 5kV-15kV Copper Conductors Cable

Select gauge from drop-down menu for prices:

Superior Essex Cable EPR/CTS/PVC Power Type MV-105,3 Conductor 5kV-15kV Copper Conductors Cable

Product Details

The Superior Essex 3 Conductor MV-105 Power Cables consist of fully annealed bare copper Class B stranded conductors, covered with ethylene propylene rubber (EPR), copper tape shield, and black PVC jacket. These cables are used in industrial power circuits.

Features:
• Rated at 105°C wet or dry
• Excellent corona resistance
• High dielectric strength
• Low moisture absorption
• Low dielectric loss
• Excellent sunlight resistance
• For CT USE per UL® 1072
• Meets cold bend test at -35°C
• For direct burial applications

Specifications:
Conductor Count: 3 conductor

Conductor: Full annealed bare copper Class B compressed strand (filled or unfilled) Also available with copper Class B compact strand

Gauge Sizes: Available in 2 AWG through 750 kcmil

Conductor Strand Shield: Extruded thermoset semi-conducting polymer over the conductor

Insulation: Ethylene Propylene Rubber (EPR)

Insulation Shield: Extruded thermoset semi-conducting polymer over the insulation

Phase Identification: Color ribbons in each phase (standard: black-red-blue)

Shield: 5 mil annealed copper tape helically applied with a 25% overlap

Fillers: Non-hygroscopic fillers, as necessary to obtain a circular cross section

Ground Conductor: Uninsulated bare copper ground

Overall Jacket: Polyvinyl Chloride (PVC)

Jacket Marking: 00000 FT SUPERIOR ESSEX XXAWG (or XXXKCMIL) 3/C XXKV XXX% INSUL LEVEL XXXMILS EPR/PVC JKT TYPE MV-105 FOR CT USE (UL) SUN RES DIR BUR MADE IN USA MMDDYYYY (LIGHTNING BOLT)

Packaging: Non-returnable wood reels in a variety of lengths and dimensions

Performance Compliances: 
• ASTM B8
• UL 1072
• UL 1685 (flame compliance)
• ICEA S-93-639/NEMA WC74
• ICEA S-97-682
• AEIC CS8
• NEC

Other Compliances: 
• EPA 40 CFR, Part 261
• OSHA

Applications:
• In conduit, duct, free air, and raceways, primary installations include cable trays, and outdoor locations
• In wet or dry locations
• Approved for Class I, Div. 2 industrial hazardous locations per NEC
• Designed to operate continuously at a conductor temperature not exceeding
• 105°C for normal operations
• 140°C for emergency overload
• 250°C for short circuit

conductor
size awg
/kcmil
nominal
conductor
diameter¹
in (mm)
nominal
insulation
diameter¹
in (mm)
ground
wire
awg
nominal
jacket
thickness¹
in (mm)
nominal
overall
diameter¹
in (mm)
nominal
net weight¹
lbs/kft
(kg/km)
ampacity superior essex
cable
part number
conduit
in air²
under
ground
duct³
tray4
Copper Cdr 5kV 133%/8kV 100% I.L., 115-mils, Shielded
2 0.280 (7.1) 0.563 (14.31) 6 0.080 (2.03) 1.614 (41.0) 1644 (2446) 165 160 185 E8FLR-021B03CB00
1 0.319 (8.1) 0.602 (15.29) 4 0.080 (2.03) 1.762 (44.8) 1976 (2940) 185 185 210 E8FLR-011B03CB00
1/0 0.358 (9.1) 0.642 (16.31) 4 0.080 (2.03) 1.848 (46.9) 2268 (3375) 215 210 240 E8FLR-1A1B03CB00
2/0 0.401 (10.2) 0.685 (17.41) 4 0.080 (2.03) 1.940 (49.3) 2594 (3860) 245 235 275 E8FLR-2A1B03CB00
3/0 0.451 (11.5) 0.736 (18.69) 3 0.080 (2.03) 2.050 (52.1) 3033 (4513) 280 270 315 E8FLR-3A1B03CB00
4/0 0.507 (12.9) 0.792 (20.12) 3 0.110 (2.79) 2.170 (55.1) 3529 (5252) 320 305 360 E8FLR-4A1B03CB00
250 0.552 (14.0) 0.838 (21.29) 2 0.110 (2.79) 2.269 (57.6) 4004 (5958) 350 335 400 E8FLR-A11B03CB00
350 0.654 (16.6) 0.941 (23.91) 2 0.110 (2.79) 2.491 (63.3) 5245 (7805) 430 400 490 E8FLR-A31B03CB00
500 0.781 (19.8) 1.069 (27.15) 1 0.140 (3.55) 2.825 (71.7) 7058 (11616) 525 485 600 E8FLR-A61B03CB00
750 0.958 (24.3) 1.248 (31.70) 1/0 0.140 (3.55) 3.140 (79.8) 9833 (14633) 635 585 745 E8FLR-B21B03CB00
Copper Cdr 15kV 133% I.L., 220-mils, Shielded
2 0.280 (7.1) 0.793 (20.14) 6 0.110 (2.79) 2.172 (55.2) 2434 (3623) 165 160 185 E8JLR-021B03CB00
1 0.319 (8.1) 0.832 (21.13) 4 0.110 (2.79) 2.256 (57.3) 2749 (4091) 185 185 210 E8JLR-011B03CB00
1/0 0.358 (9.1) 0.872 (22.15) 4 0.110 (2.79) 2.342 (59.5) 3069 (4567) 215 210 240 E8JLR-1A1B03CB00
2/0 0.401 (10.2) 0.915 (23.24) 4 0.110 (2.79) 2.435 (61.8) 3429 (5103) 245 235 275 E8JLR-2A1B03CB00
3/0 0.451 (11.5) 0.966 (24.54) 3 0.110 (2.79) 2.544 (64.6) 3916 (5827) 280 270 315 E8JLR-3A1B03CB00
4/0 0.507 (12.9) 1.022 (25.96) 3 0.110 (2.79) 2.665 (67.7) 4475 (6659) 320 305 360 E8JLR-4A1B03CB00
250 0.552 (14.0) 1.068 (27.13) 2 0.110 (2.79) 2.824 (71.7) 5168 (7690) 350 335 400 E8JLR-A11B03CB00
350 0.654 (16.6) 1.171 (29.74) 2 0.140 (3.55) 3.045 (77.3) 6289 (9359) 430 400 490 E8JLR-A31B03CB00
500 0.781 (19.8) 1.299 (32.99) 1 0.140 (3.55) 3.320 (84.3) 8102 (12057) 525 485 600 E8JLR-A61B03CB00
750 0.958 (24.3) 1.478 (37.50) 1/0 0.140 (3.55) 3.610 (91.7) 10978 (16337) 635 585 745 E8JLR-B21B03CB00

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.