Power Cable 5KV/8KV UL Type MV-105, 105°C Three Conductor, Shielded EPR Insulation, PVC Jacket 5KV 133%, 8KV 100% Insulation Level Copper Conductor

Power Cable 5KV/8KV UL Type MV-105, 105°C Three Conductor, Shielded EPR Insulation, PVC Jacket 5KV 133%, 8KV 100% Insulation Level Copper Conductor

Select gauge from drop-down menu for prices:

Power Cable 5KV/8KV UL Type MV-105, 105°C Three Conductor, Shielded EPR Insulation, PVC Jacket 5KV 133%, 8KV 100% Insulation Level Copper Conductor

Product Details

Specifications:

  • HW213 Power Cable
  • 5KV/8KV UL Type MV-105, 105°C
  • Three Conductor, Shielded
  • EPR Insulation, PVC Jacket
  • 5KV 133%, 8KV 100% Insulation Level
  • Copper Conductors

Application:
For use in primary power and distribution circuits up to 8KV when installed in open air, conduit, duct, cable tray when CT rated, or direct buried in earth, in wet and dry locations. Used for applications in chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations and generating stations. UL approved for use at 105°C for continuous operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions.

Conductors:
Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact), with a semi-conducting conductor shield.

Insulation:
Ethylene propylene rubber (EPR) per ICEA S-97-682 with a semi-conducting insulation shield.

Shield:
Uncoated copper tape with a minimum 12.5% overlap per ICEA S-97-682.

Grounding Conductor:
Compressed soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance to UL Standard 1072.

Jacket:
Sunlight-resistant PVC per ICEA S-97-682 and UL Standard 1072.

Flame Tests:
UL and IEEE 383 70,000 BTU/hr flame test – CT-listed sizes 1/0AWG and larger.

Color Code:
ICEA Method 4

Additional Standards:

  • ICEA S-93-639
  • NEMA WC74
  • AEIC CS8
  • Federal Specification J-C-30B

Connectors:
Explosion Proof, Class I, Division 2: 424UN series – aluminum exterior components, nickel-plated brass interior components.

Note:
CT rating must be requested. CT ratings are available on all sizes.

Size (AWG
or kcmil)
No. of
Strands
Net Weight Overall Diameter
(Inches)
Insulation
Thickness (Mils)
Jacket
Thickness
 (Mils)
Copper
Grounding Wire
Insulation
Diameter
 (Inches):
Product
 Code
6 Gauge 7 1052 1.38 115 80 6 0.47 HW213 00603 /
HW21300603
4 Gauge 7 1265 1.48 115 80 6 0.52 HW213 00403 /
HW21300403
2 Gauge 7 1608 1.61 115 80 6 0.57 HW213 00203 /
HW21300203
1 Gauge 19 1989 1.75 115 110 4 0.61 HW213 00103 /
HW21300103
1/0 19 2257 1.84 115 110 4 0.65 HW213 10103 /
HW21310103
2/0 19 2609 1.93 115 110 4 0.70 HW213 20103 /
HW21320103
3/0 19 3073 2.04 115 110 3 0.75 HW213 30103 /
HW21330103
4/0 19 3598 2.16 115 110 3 0.80 HW213 40103 /
HW21340103
250 MCM 37 4094 2.30 115 110 3 0.86 HW213 25003 /
HW21325003
350 MCM 37 5288 2.52 115 110 2 0.96 HW213 35003 /
HW21335003
500 MCM 37 7256 2.89 115 140 1 1.09 HW213 50003 /
HW21350003
750 MCM 61 10128 3.77 115 140 1 1.28 HW213 75003 /
HW21375003

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question