General Cable GenFree® II High Speed Type RHH RHW-2 USE-2 LSZH XLPO Low Voltage Power Unshielded 600V UL

General Cable GenFree® II High Speed Type RHH RHW-2 USE-2 LSZH XLPO Low Voltage Power Unshielded 600V UL

Select gauge from drop-down menu for prices:

General Cable GenFree® II High Speed Type RHH RHW-2 USE-2 LSZH XLPO Low Voltage Power Unshielded 600V UL
GenFree II High Speed Type RHH RHW-2 USE-2 LSZH XLPO Low Voltage Power Unshielded 600V UL

Conductor:
• 14 AWG thru 1000 kcmil stranded annealed tinned copper per ASTM B33
• Compressed Class B stranding per ASTM B8

Insulation:
• Low-Smoke, Zero-Halogen Cross-linked Polyolefin (LSZH XLPO), black
• Colors available upon request

Applications:
• For use in closed environments or populated spaces such as auditoriums, arenas and health facilities where more stringent customer specifications for smoke and halogen-free materials are desired
• Ideally suited for use in a broad range of commercial, industrial, transit and utility applications where reliability is a major concern, where maximum performance will be demanded and where space is limited
• For use in free air, raceways or direct burial in accordance with NEC

Features:
• Rated at 90?C wet or dry
• Low-Smoke, Zero-Halogen insulation system
• Smaller cable O.D.
• Low friction for easy pulling on 8 AWG and larger
• Excellent electrical, thermal and physical properties
• Excellent moisture resistance, exceeding UL 44 requirements
• Excellent resistance to crush, compression cuts and heat deformation
• Excellent flame resistance
• Resistant to most oils and chemicals
• UV/sunlight-resistant
• Rated ST-1 for Limited Smoke per UL 44 on sizes 1/0 AWG and larger
• Stable electrical properties over a broad temperature range
• Excellent low temperature characteristics, meets cold bend and cold impact test at -40?C

Compliances:
Industry Compliances:
• National Electrical Code (NEC)
• “FOR CT USE” on 1/0 AWG and larger in accordance with NEC
• UL 44 Type RHH/RHW-2, UL File # E90494
• c(UL) Type RW90 1 kV UL File # E90494
• UL 854 Type USE-2, UL File # E90499
• UL Listed Low-Smoke, Halogen-Free per UL 2885
• Limited Smoke rating per UL 44 and UL 1685
• ICEA T-33-655 smoke, halogen and acid gas requirements
• Halogen content of cable material does not exceed 0.2%, and acid gas equivalent does not exceed 2.0%, according to the test method of MIL-C-24643
• ICEA S-95-658/NEMA WC70
• UL Listed VW-1

Flame Test Compliances:
• For 1/0 AWG and larger: IEEE 383
• IEEE 1202/CSA FT4
• UL 1685
• UL 44 VW-1

Other Compliances:
• EPA 40 CFR, Part 261 for leachable lead content per TCLP
• OSHA Acceptable
• RoHS Compliant
• NFPA 130 (1/0 & larger sizes)
• NES 713

Packaging: Material cut to length and shipped on non-returnable wood reels