Corning 1 to 2 Fiber Singlemode SST-Drop Indoor/Outdoor Gel-Free Dielectric Cable

Corning 1 to 2 Fiber Singlemode SST-Drop Indoor/Outdoor Gel-Free Dielectric Cable

Corning 1 to 2 Fiber Singlemode SST-Drop Indoor/Outdoor Gel-Free Dielectric Cable

Corning SST-Drop™ indoor/outdoor dielectric cables provide the simple installation offered by standard SST-Drop cables designed for rugged outdoor environments and compact drop cables designed for challenging indoor bend environments. The design features a gel-free, fully waterblocked, UV-resistant 2.9 mm riser-rated (OFNR) drop cable centered inside a traditional SST-Drop dielectric cable. Designed to meet industry-standard requirements for outdoor and indoor drop cables, the product eliminates the need for termination to transition from the outdoor environment to an indoor ONT. This dielectric version eliminates any bonding and grounding requirements and is suitable for aerial, direct buried and duct installation. A toneable version is also available.

The product is available in convenient contractor-sized packaging for easy field deployment and features bend-insenstive single-mode fiber, which enables installers to route the subunit around tight corners down to 5 mm (0.2 in) radius inside the home.

Features And Benefits:
2.9 mm subunit in a rugged outdoor cable - Eliminates need for termination transition in indoor ONT
Crush resistance - Fiber protection and signal integrity
UV-resistant, flame-retardant inner jacket - Rugged, durable and easy to strip
Dielectric - Eliminates bonding and grounding requirements
Small subunit diameter and bend-radius - Easy installation in space-constrained areas

General Specifications:
• Environment: Indoor/Outdoor
• Application: Self-Supporting, Aerial, Direct Buried, Duct, General Purpose Horizontal, Vertical Riser
• Cable Type: Drop
• Fiber Category: ClearCurve® ZBL Single-mode (OS2)
• Product Type: Self-Supporting

Standards:
• Approvals and Listings: Compact Drop Subunit listed to National Electrical Code® (NEC®) OFNR, FT-4
• Design and Test Criteria: ANSI/ICEA S-110-717, Telcordia GR-20-CORE, Telcordia GR-409-CORE

Temperature Range:
• Storage: -40 °C to 70 °C (-40 °F to 158 °F )
• Installation: -30 °C to 70 °C (-22 °F to 158 °F )
• Operation: -40 °C to 70 °C (-40 °F to 158 °F )

Mechanical Characteristics Cable:
• Max. Tensile Strength, Short-Term: 1350 N (300 lbf)
• Max. Tensile Strength, Long-Term: 400 N (90 lbf)
• Nominal Outer Diameter: 14.3 mm (0.56 in)
• Nominal Cable Height: 8.1 mm x4.5 mm (0.32 in x0.17 in)
• Outer Cable Minimum Bend-Radius Operation: 80 mm (3.15 in)
• Inner Cable Minimum Bend-Radius Operation: 5 mm (0.2 in)
• Min. Bend Radius Operation: 80 mm (3.15 in)

Maximum Span with One-Percent Installation Sag
• Maximum Span with 1% Installation Sag, NESC Light: 101 m (330 ft)
• Maximum Span with 1% Installation Sag, NESC Medium: 78 m (255 ft)
• Maximum Span with 1% Installation Sag, NESC Heavy: 46 m (150 ft)

Chemical Characteristics
• RoHS: Free of hazardous substances according to RoHS 2011/65/EU

Shipping Information
• Convenient Contractor-sized Packaging Length: 609.6 m gross weight 72 lbs; no specialized equipment needed (2,000 ft gross weight 72 lbs; no specialized equipment needed )
• Traditional Bulk Packaging: up to 5000 m typically require reel payoff equipment

fiber count fiber category weight corning cable
part number