General Cable Anaconda® Brand Type SHD-BGC Power Shielded Round Portable w/Extensible Ground-Check EPR CPE 5000 Volts Three Conductor

General Cable Anaconda® Brand Type SHD-BGC Power Shielded Round Portable w/Extensible Ground-Check EPR CPE 5000 Volts Three Conductor

Product Details

Conductor: 1 AWG thru 500 kcmil coated annealed copper, bunched wires, rope-lay-stranded per ASTM B172

Extruded Strand Shield (ESS): Extruded thermosetting semi-conducting stress control layer over conductor
 
Insulation: Ethylene Propylene Rubber (EPR) insulation colored for contrasting with black conducting layer 

Insulation Shield: A flexible coated copper/textile braid shield is applied over a non-conducting overlapped tape

Ground-Check Conductor:
• Coated copper, specially stranded to provide extensibility without sustaining tensile load, thereby providing maximum resistance to flex fatigue
• Insulated with high-strength polypropylene and placed in the center interstice

Grounding Conductors: Three coated copper, rope-lay-stranded per ASTM B172 in contact with the flexible braid shield

Jacket: Reinforced, two-layer, extra-heavy-duty, leadcured Chlorinated Polyethylene (CPE)

Jacket Marking: GENERAL CABLE® ANACONDA® BRAND (SIZE) 3/C TYPE SHD-BGC 5000 VOLTS (-50C) FT1 FT5 CSA LR 27161 P-7K-102-046 MSHA

Options:
• Colored jackets are available
• TPU (Thermoplastic Polyurethane) jacket
• Anamaxx® jacket 

Applications:
• Designed for use as a trailing cable on AC mining equipment:
- Where maximum safety is mandatory, including underground mining machines where induced voltages in an unbalanced grounding system could be hazardous
- On low- and medium-voltage AC circuits where shielding is desired or required

Features:
• Flexible insulation shield provides shock hazard protection
• Symmetrical grounding system does not produce induced voltages when operating in a balanced 3-phase system 
• Excellent heat, moisture, steam, oil, chemical and radiation resistance
• Flexible for easy handling
• Resists cutting, impact, abrasion, flame and sunlight
• Excellent thermal stability and physical properties over a broad temperature range
• Two-layer jacket is reinforced to provide maximum protection from mechanical damage —the cause of most portable cable failures 

Compliances:
• ICEA S-75-381 Portable and Power Feeder Cables for use in mines and similar applications
• Meets flame test requirements and is accepted for listing by MSHA
• Approved by the Pennsylvania Department of Environmental Protection 
• Meets CAN/CSA C22.2 No. 96 Portable Power Cables and is certified by Natural Resources Canada

Packaging: Material cut to length and shipped on nonreturnable reels
cond. size
(awg /Kcmil)
no. of cond. ampacity general cable and
anaconda brand
part number
Action
1 3 184 16299.060100.ca Request a Quote
1/0 3 211 16299.065100.ca Request a Quote
2/0 3 243 16252.530102.ca Request a Quote
3/0 3 279 16299.065300.ca Request a Quote
4/0 3 321 16299.065400.ca Request a Quote
250 3 355 16299.066000.ca Request a Quote
300 3 398 16299.066100.ca Request a Quote
350 3 435 16299.066200.ca Request a Quote
500 3 536 16299.066500.ca Request a Quote

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question