Description:
• 22 AWG stranded (7x30) TC conductors, FPE insulation (data), STP (Data) w/Beldfoil®, TC drain wire, 18 AWG (16x30) TC conductors, unshielded (power) pair, F-R PVC insulation (power), F-R PVC Jacket (Available in Black, White, or Aqua).

Insulation:
• Trade Name: Datalene®
• Materials: HDFPE - High Density Foam Polyethylene (22 AWG) & F-R PVC - Flame Retardant Polyvinyl Chloride (18 AWG)
• Wall Thickness (in.): 0.025 (22 AWG) & 0.013 (18 AWG)

Inner Shield:
• Layer #: 22 AWG Pair
• Trade Name: Beldfoil®
• Type: Tape
• Material: Aluminum Foil-Polyester Tape

Inner Shield Drain Wire AWG:
• AWG: 24
• Stranding: 7x32
• Conductor Material: Tinned Copper

Outer Jacket:
• Material: F-R PVC - Flame Retardant Polyvinyl Chloride
• Ripcord: Yes

Mechnical Characteristics (Overall):
• Operating Temperature Range: -20°C To +75°C
• Non-UL Temperature Rating: 75°C
• Bulk Cable Weight: 40 lbs/1000 ft.
• Max. Recommended Pulling Tension: 59.800 lbs.
• Min. Bend Radius/Minor Axis: 2.500 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards & Environmental Programs:
• NEC/(UL) Specification: CMR
• CEC/C(UL) Specification: CMG
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire & Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 100
• Nom. Inductance: 0.232 (22 AWG) & 0.168 (18 AWG)
• Nom. Capacitance Conductor to Conductor (pF/ft): 14 (22 AWG) & 29 (18 AWG)
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/ft): 38 (22 AWG)
• Nom. Conductor DCR @ 20°C (Ohm/1000 ft): 16.3 (22 AWG) & 6.9 (18 AWG)
• Max.Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 3.8 Amps per conductor @ 25°C (22 AWG); 7.2 Amps per conductor @ 25°C (18 AWG)

Flame Test:
• UL Flame Test: UL1666 Vertical Shaft
• CSA Flame Test: FT4

Plenum/Non-Plenum:
• Plenum (Y/N): No
• Plenum Number: 1502P

Benefits And Features:
• Belden offers more than 25 variations for DMX / RS-485 applications
• Many of Belden's lighting cables are designed for industrial standards, and their rugged and resistant cable options are suitable for many indoor and outdoor lighting challenges

technical specification:
awg 22 and 18
# pair 1
stranding 7x30 and 16x30
no. of conductors 4
conductor material tinned copper
dia. (in.) -
outer shield - type -
outer shield - material Unshielded
overall cable - nominal dia. (in.) 0.250