• Prysmian and Draka Cable XPRLTM Oil and Gas Utility Low Temp Cable

    Product Details

    Overview: The double jacket construction offers premium mechanical protection from tensile and compression forces. The jacket material is formulated specifically to protect the fibers from a variety of chemicals/solvents and makes this cable ideal for petrochemical facilities and industrial complexes. This cable is extremely versatile, may be utilized in low temperature applications down to -50°C (-58°F) and/or in properly engineered self-supported aerial applications.

    Product Snapshot:

    Applications: Extremely rugged indoor/outdoor cable providing unsurpassed performance in the most challenging applications where extreme tensile, crush, or temperature exposure are present. Suitable for installations in a cable tray per NFPA 70. 

    Flame Rating: General purpose OFNG / FT4

    Fiber Count: 2 to 288

    Fiber Types: Single-mode (ESMF, bend-Insensitive) multimode (62.5/125-OM1, 50/125-OM2+, OM3 & OM4)

    Performance: ANSI/ICEA S-104-696, CSA C22.2 No 230, UL-1685 Telcordia GR-20, RoHS compliant

    Features and Benefits:
    • Proven stranded loose tube cable design for long term reliability
    • Flame-retardant, chemical resistant, black UV-resistant outer jacket
    • Hydrocarbon (kerosene, gasoline, lubricating oil) resistant
    • Resistant to jet fuel and de-icing chemicals for airport applications
    • Cable core utilizing dry-waterblock technology to improve handle ability
    • Available with bend-insensitive single-mode and multimode optical fibers
    • Smaller & lighter than comparable metallic armored designs
    • Resists chemical degradation when placed in industrial environments or waste water runoff systems
    • Suitable for tray installations per NFPA 70
    • Suitable for self support applications

    Dielectric (Double Jacket) XPRLTM Series | OFNG/FT4
    fiber count number of
    buffer tubes
    fibers
    per unit
    diameter
    inches (mm)
    cable weight
    lb/kft (kg/km)
    bend radius
    under load
    inches (cm)
    bend radius
    no load
    inches (cm)
    2 to 72 6 12 0.60 (15.3) 159 (237) 12.0 (30.5) 6.0 (15.3)
    74 to 84 7 12 0.64 (16.2) 176 (262) 12.8 (32.6) 6.4 (16.3)
    86 to 96 8 12 0.67 (17.1) 198 (294) 13.4 (34.1) 6.7 (17.1)
    98 to 108 9 12 0.71 (17.9) 216 (322) 14.2 (36.1) 7.1 (18.1)
    110 to 120 10 12 0.74 (18.8) 238 (354) 14.8 (37.6) 7.4 (18.4)
    122 to 132 11 12 0.78 (19.7) 260 (387) 15.6 (39.7) 7.8 (19.9)
    134 to 144 12 12 0.83 (21.0) 294 (438) 16.6 (42.2) 8.3 (21.1)
    146 to 216 12 / 6 12 0.81 (20.5) 267 (398) 16.2 (41.2) 8.1 (20.6)
    218 to 264 14 / 8 12 0.90 (22.8) 333 (496) 18.0 (45.8) 9.0 (22.9)
    266 to 288 15 / 9 12 0.93 (23.7) 358 (532) 18.6 (47.3) 9.3 (23.7)

    Mechanical Specifications
    maximum installation load: maximum operation load: crush resistance: impact force resistance: cold impact load:
    1000 lbf (4500 n) 300 lbf (1335 n) 4500 n 11.8 n*m 5.88 n*m at -22° f (-30° c)

    Temperature Range
    shipping and storage: installation: operation:
    -58° f to +158° f -22° f to +140° f -58° f to +158° f
    (-50° c to +70° c) (-30° c to +60° c) (-50° c to +70° c)

    nesc light
    1.5% initial sag
    csa medium a
    1.5% initial sag
    csa heavy a
    1.5% initial sag
    prysmian and draka cable
    part numbers
    fiber count span(m) weather load
    mrcl (n)
    installation
    tension (n)
    span(m) weather load
    mrcl (n)
    installation
    tension (n)
    span
    (m)
    weather load
    mrcl (n)
    installation
    tension (n)
    dead end aluminum
    support
    2 - 72 130 4026 2514 87 4026 1700 62 4026 1215 2872007C1E1 4450102
    74 to 84 120 4026 2585 83 4026 1771 60 4026 1281 2872008C1E1 4450103
    86 to 96 133 4827 3194 93 4827 2247 68 4827 1646 2872009C1E1 4450103
    98 to 108 123 4827 3257 88 4827 2331 66 4827 1726 2872010C1E1 4450104
    110 to 120 115 4827 3332 83 4827 2411 62 4827 1811 2872011C1E1 4450104
    122 to 132 107 4827 3390 79 4827 2491 60 4827 1895 2872011C1E1 4450105
    134 to 144 97 4827 3479 73 4827 2603 56 4827 2011 2872012C1E1 4450106
    146 to 216 87 4026 2821 64 4026 2087 49 4026 1588 2872012C1E1 4450105
    218 to 264 87 4827 3541 66 4827 2687 52 4827 2118 2872014C1E1 4450106
    266 to 288 82 4827 3586 63 4827 2749 50 4827 2180 2872014C1E1 4450107

    Mechanical Specifications
    maximum installation load: maximum operation load: crush resistance: impact force resistance: cold impact load:
    1000 lbf (4500 n) 300 lbf (1335 n) 4500 n 11.8 n*m 5.88 n*m at -22° f (-30° c)

    Temperature Range
    shipping and storage: installation: operation:
    -58° f to +158° f -22° f to +140° f -58° f to +158° f
    (-50° c to +70° c) (-30° c to +60° c) (-50° c to +70° c)

    Chemical Resistance Performance
    compound test criteria
    astm no. 2 oil
    kerosene
    mil-t-5624n jp-4 (jet fuel)
    mil-h-5606 hydraulic fluid
    vegetation killer
    de-icing fluid
    hydrogen sulfide (h2s)
    96 hours at 100°c
    168 hours at 50°c
    168 hours at 50°c
    168 hours at 50°c
    168 hours at 50°c
    24 hours at 50°c
    24 hours at 100°c

    Quick Quote Form 

    * Indicates required field

    Receive A Response In 5 Minutes Or Less During Regular Business Hours

    Captcha Image

    This product has no related products.

Request a Quote

Receive A Response In 5 Minutes Or Less During Business Hours

Sign up for our newsletter

Register with Nassau today.

Subscribe to Newsletter