Helukabel 4/0 AWG 4 Cores JZ-604-YCY TC PVC Power Cable TC-ER NFPA 79 90C 600V EMC-Preferred Type, Screened Cable 69825

Helukabel 4/0 AWG 4 Cores JZ-604-YCY TC PVC Power Cable TC-ER NFPA 79 90C 600V EMC-Preferred Type, Screened Cable 69825

Select gauge from drop-down menu for prices:

Helukabel 4/0 AWG 4 Cores JZ-604-YCY TC PVC Power Cable TC-ER NFPA 79 90C 600V EMC-Preferred Type, Screened Cable 69825
Helukabel 4/0 AWG 4 Cores JZ-604-YCY TC PVC Power Cable TC-ER NFPA 79 90C 600V EMC-Preferred Type, Screened Cable 69825

Technical Data:
• PVC power cable, screened to UL Std.1277 TRAY CABLE

Multinorm
• Also conforms to the following standards: AWM-Style 2587 to UL Std.758 and CSA C22.2 No 210 I/II A/B 90°C 600 V

Temperature Range
• Dry environment
• Flexing -5°C to +90°C
• Fixed installation -25°C to +90°C
• Wet environment
• Flexing -5°C to +75°C
• Fixed installation -25°C to +75°C

Nominal Voltage
• UL 600 V

Test Voltage
• 3000 V

Breakdown Voltage
• Min. 6000 V

Minimum Bending Radius
• 10x cable Ø

Radiation Resistance
• Up to 80x106 cJ/kg (up to 80 Mrad)

Coupling Resistance
• Max. 250 Ohm/km

Cable Structure:
• Bare copper, fine wire conductors, acc. to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5
• Core insulation of special PVC class 12 B to tab.50.155 acc. to UL Std.1581 type THHW acc. to UL Std.83
• Core identification to DIN VDE 0293 black cores with continuous white numbering
• GN-YE conductor, 3 cores and above in the outer layer
• Cores stranded in layers with optimal lay length
• PVC-inner sheath acc. to UL Std.1277 tab.11.2
• Tinned copper braided screening, approx. 85% coverage
• Outer sheath of special PVC acc. to UL Std.1277 tab.11.2,
• Sheath colour: black (RAL 9005)
• With meter marking

Properties:
• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
• UV resistant

Note:
• Self-extinguishing and flame retardant acc. to CSA FT4
• UL OIL RES I OIL RES II
• Class 1 Div. 2 per NEC Art. 336, 392, 501

Application:
• USA NFPA 79 conformant flexible power cables up to 600 V, for all machinery in tool and plant constuction, suitable for installation in dry, humid and damp environments, in the open and in pipes. For underground installation and for open, unprotected installation from the cable rack to machines and industrial plants.

Technical Specification
AWG  4/0
No.Cores x cross-sec.mm² 4 G 120
Outerø app.mm 59,5 
Cop. weight kg/km 5231,0 
Weight app. kg/km 8256,0
Helukabel Part Number 69825
5231,0 