Belden 10GX53F Cable 23 AWG 4 Pairs Category 6A F/UTP Non-Bonded Pair Enhanced Multi Conductor Solid Bare Copper Flamarrest Jacket Cable

Belden 10GX53F Cable 23 AWG 4 Pairs Category 6A F/UTP Non-Bonded Pair Enhanced Multi Conductor Solid Bare Copper Flamarrest Jacket Cable

Select gauge from drop-down menu for prices:

Belden 10GX53F Cable 23 AWG 4 Pairs Category 6A F/UTP Non-Bonded Pair Enhanced Multi Conductor Solid Bare Copper Flamarrest Jacket Cable
Belden 10GX53F Cable 23 AWG 4 Pairs Category 6A F/UTP Non-Bonded Pair Enhanced Multi Conductor Solid Bare Copper Flamarrest Jacket Cable

Description:
• CAT6A (625MHz), 4 Unbonded Pairs, F/UTP-Foil Shielded, Plenum-CMP, Premise Horizontal Cable, 23 AWG Solid Bare Copper Conductors, FEP Insulation, Patented EquiSpline™, Overall Foil Screen with Drain Wire, Ripcord, Flamarrest® Jacket.

Insulation:
• Material: FEP

Outer Shield Drain Wire AWG:
• AWG: 26
• Stranding: 7x34
• Conductor Material: Tinned Copper

Outer Jacket:
• Material: Flamarrrest (R) PVC - Polyvinyl Chloride
• Nom. Diameter (in.): 0.275
• Outer Jacket Ripcord: Yes

Usage (Overall):
Applications:
• Premise Horizontal Cable, 10 Gigabit Ethernet, Wireless, Wi-Fi, 100Base TX, 100Base VG ANYLAN, 155ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU Digital Audio AES51, RS-422, Noisy Environments, PoE, PoE+.

Mechanical Characteristics (Overall):
• Storage Temperature Range: -20°C To +75°C
• Installation Temperature Range: +5°C To +50°C
• Operating Temperature Range: -20°C To +75°C
• Bulk Cable Weight: 38 lbs/1000 ft.
• Max. Recommended Pulling Tension: 45 lbs.
• Min. Bend Radius/Minor Axis: 1.500 in.
• Min. Bend/Installation: 2.750 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMP
• CEC/C(UL) Specification: CMP
• EU Directive 2011/65/EU (ROHS II): Yes
• Other Standards: ISO/IEC 11801 ed 2 Amendment 2:2010 Class EA
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 03/27/2014
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Telecommunications Standards: Category 6A - TIA 568.C.2
• ANSI Specification: ANSI/TIA 568-C.2 Category 6A
• Other Specification: C(UL)US CMP 105C OR (UL) CMP-LP (0.7A) OR CL3P-LP (0.7A)

Electrical Characteristics (Overall):
• Nom. Mutual Capacitance (pF/ft): 17.000
• Maximum Capacitance Unbalance (pF/100 m): 90
• Nominal Velocity of Propagation: VP (%): 68.000
• Maximum Delay (ns/100 m): 538 @ 100MHz
• Max. Delay Skew (ns/100 m): 45.000
• Maximum Conductor DC Resistance @ 20°C (Ohm/100 ft): 8.200
• Max. Operating Voltage - UL: 300 V RMS

Flame Test:
• UL Flame Test: NFPA 262 Plenum Flame Test (UL910)(FT6)
• C/(UL) Flame Test: FT6
• CSA Flame Test: FT6

Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: No
• Suitability - Buiral: No
• Sunlight Resistance: No
• Non-halogenated: No

Plenum/Non-Plenum:
• Plenum (Y/N): Yes
• Non-Plenum Number: 10GX52F

technical specification:
awg 23
# pairs 4
stranding solid
no. of conductors 8
conductor material bare copper
outer shield - type tape
outer shield - material aluminum-polyester tape
overall cable - nominal diameter (in.) -
belden cable part number 10GX53F