FX5Q001 - Configurable Pressure Sensor with Integrated Temperature Measurement
FX5Q001 - Configurable Pressure Sensor with Integrated Temperature Measurement
SKU: SKU: FX5Q001 Download PDF
- FX5Q001 - Configurable Pressure Sensor with Integrated Temperature Measurement
- FX5Q001 - Configurable Pressure Sensor with Integrated Temperature Measurement
Couldn't load pickup availability

*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Description:
Introducing the weFlux² pressure sensors, which incorporate an advanced measuring cell equipped with a built-in temperature element for tracking both relative pressure and temperature across different media These sensors are highly customizable; they can be tailored to feature either two switching outputs or a combination of one switching output alongside one analog output, depending on your specific application requirements.
With extensive configurability, the weFlux² allows users to modify sensor parameters, filtering capabilities, output functions, and measurement units (such as bar, PSI, or Pascal) to meet their needs perfectly.
Features and Benefits:
•Pressure and temperature measurement with a single sensor.
•Individual parameter configuration via IO-Link 1.1.
•Compact, laser-welded stainless steel 316L housing.
•Temperature-compensated pressure measurement.
Specifications:
| Measuring Range | -1 ... 10 bar |
| Measurement Type | relative |
| Maximum overload pressure | 20 bar |
| Bursting pressure | 30 bar |
| Medium | Liquids, gases |
| Temperature Measurement Range | -40 ... 125 °C |
| Response time (t90) Temp | < 1 s |
| Pressure response time (t90) | < 10 ms |
| Temperature Measurement Accuracy | < ± 1 °C |
| Measuring error (total) | ± 0.5 % |
| Hysteresis | < ± 0.1 % |
| Linearity Deviation | < ± 0.5 % |
| Zero-point error | < ± 0.1 % |
| Repeat Accuracy | < ± 0.1 % |
| Temperature coefficient zero-point | <± 0,05% /10K |
| Temperature coefficient range | <± 0,05% /10K |
| Long-term stability | < ± 0.1 % |
| Temperature of medium | -40 ... 125 °C |
| Ambient temperature | -25 ... 80 °C |
| Storage temperature | -25 ... 80 °C |
| EMC | DIN EN 61326-2-3 |
| Shock resistance per DIN IEC 68-2-27 | 50 g / 11 ms |
| Vibration resistance per DIN IEC 60068-2-6 | 10 g (10...2000 Hz) |
| Supply Voltage | 12 ... 32 V DC |
| Current Consumption (Ub = 24 V) | < 15 mA |
| Number of Switching Outputs | 2 |
| Switching Output / Switching Current | 100 mA |
| Switching Output Voltage Drop | < 1.5 V |
| Number of analog outputs | 1 |
| Analog Output | 4...20 mA |
| Signal source | Pressure |
| Resolution | > 11 bit |
| Current Output Load Resistance | < 500 Ohm |
| Voltage output load resistance | > 1 kOhm |
| Interface | IO-Link V1.1 |
| Short Circuit Protection | yes |
| Reverse Polarity Protection | yes |
| Protection Class | III |
| Setting Method | IO-Link |
| Sensor element | Ceramic membrane |
| Housing Material | Stainless steel, V4A (1.4404/316L) |
| Material in contact with media | Stainless steel, V4A (1.4404 / 316L), Rubber, FKM, Ceramic |
| Degree of Protection | IP65 |
| Connection | M12 × 1; 4-pin |
| Process Connection | G3/4"; front |
| Seal material | Fluororubber, FKM |
| MTTFd (EN ISO 13849-1) | 1,157.11 a |
| Adjustable parameters | Analog output: 0...10 V, 4...20 mA, Signal source: Pressure, Temperature |
| Circuit | NC, NC/NO, NO |
| Other parameters | 2 switching points |