Description:
• 28 AWG stranded (7x36) TC conductors, polypropylene insulation, overall Beldfoil® (100% coverage) + TC braid shield (90% coverage), 28 AWG stranded TC drain wire, PVC jacket.

Insulation:
• Material: PP - Polylpropylene
• Wall Thickness (in.): 0.009

Outer Shield Drain Wire AWG:
• AWG: 28
• Stranding: 7x36
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (in.): 0.035

Mechanical Characteristics (Overall):
• Operating Temperature Range: -20°C To +60°C
• UL Temperature Rating: 60°C (UL AWM Style 2960)
• Bulk Cable Weight: 58 lbs/1000 ft.
• Max. Recommended Pulling Tension: 105 lbs.
• Min. Bend Radius/Minor Axis: 3.250 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CL2
• AWM Specification: UL Style 2960 (30 V 60°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 100
• Nom. Inductance (μH/ft): 0.19
• Nom. Capacitance Conductor to Conductor (pF/ft): 15.5
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/ft): 27.5
• Nominal Velocity of Propagation: VP (%): 66
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 64.9
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 2.8
• Max. Operating Voltage - UL: 300 V RMS (UL AWM Style 2960)
• Max. Operating Voltage - UL: 150 V RMS (CL2)
• Max. Recommended Current: 0.65 Amps/Conductor @ 25°C

Flame Test:
• UL Flame Test: UL1685 UL Loading

Plenum/Non-Plenum:
• Plenum(Y/N): No

technical specification:
awg 28
# pairs 12
stranding 7x36
no. of conductors 24
conductor material tinned copper
diameter (in.) -
outer shield - type tape
outer shield - material aluminum foil-polyester tape
overall cable - nominal diameter (in.) 0.319
belden cable part number 9812