Belden 3105T Cable 22 AWG 1 Pair RS-485 PLTC/CMG EIA Industrial Multi Conductor Stranded 7x30 UV Resistant LSZH Jacket Cable

Belden 3105T Cable 22 AWG 1 Pair RS-485 PLTC/CMG EIA Industrial Multi Conductor Stranded 7x30 UV Resistant LSZH Jacket Cable

Select gauge from drop-down menu for prices:

Belden 3105T Cable 22 AWG 1 Pair RS-485 PLTC/CMG EIA Industrial Multi Conductor Stranded 7x30 UV Resistant LSZH Jacket Cable
Belden 3105T Cable 22 AWG 1 Pair RS-485 PLTC/CMG EIA Industrial Multi Conductor Stranded 7x30 UV Resistant LSZH Jacket Cable

Description:
• 22 AWG stranded (7x30) tinned copper conductors, Datalene® insulation, twisted pairs, overall Beldfoil® shield (100% coverage) plus a tinned copper braid (65% coverage), drain wire, UV resistant LSZH jacket.

Insulation:
• Material: FHDPE - Foam High Density Polyethylene

Outer Shield Drain Wire AWG:
• AWG: 22
• Stranding: 7x30
• Material: TC - Tinned Copper

Outer Jacket:
• Material: LSZH - Low Smoke Zero Halogen

Mechanical Characteristics (Overall):
• Operating Temperature Range: -20°C To +60°C
• Bulk Cable Weight: 115 lbs/1000 ft.
• Max. Recommended Pulling Tension: 60 lbs.
• Min. Bend Radius/Minor Axis: 4.500 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMG, PLTC
• CEC/C(UL) Specification: CMG
• EU Directive 2011/65/EU (ROHS II): Yes
• IEEE Specification: 45
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 120
• Nom. Capacitance Conductor to Conductor (pF/ft): 11.0
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/ft): 20.9
• Nominal Velocity of Propagation: VP (%): 78
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 14.7
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 2.8
• Max. Operating Voltage - UL: 300 V (NEC Type PLTC)
• Max. Operating Voltage - UL: 300 V RMS (NEC Type CM)
• Max. Recommended Current: 2.7 Amps/Conductor @ 25°C

Flame Test:
• UL Flame Test: UL1685 UL Loading
• CSA Flame Test: FT1
• IEC Flame Test: 60332-3-22 (Category A)

Suitability:
• Sunlight - Resistance: Yes

Plenum/Non-Plenum:
• Plenum(Y/N): No

technical specification:
awg 22
# pairs 1
stranding 7x30
no. of conductors 2
conductor material tinned copper
diameter (in.) 0.030
outer shield - type tape
outer shield - material aluminum foil-polyester tape
overall cable - nominal diameter (in.) 0.450
belden cable part number 3105T

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question