Belden 82120 Cable 18 AWG 1 Coax RG-6 Plenum Duofoil Flamarrest Jacket Cable

Belden 82120 Cable 18 AWG 1 Coax RG-6 Plenum Duofoil Flamarrest Jacket Cable

Select gauge from drop-down menu for prices:

Belden 82120 Cable 18 AWG 1 Coax RG-6 Plenum Duofoil Flamarrest Jacket Cable
Belden 82120 Cable 18 AWG 1 Coax RG-6 Plenum Duofoil Flamarrest Jacket Cable

Description:
• 18 AWG solid .040" bare copper-covered steel conductor, plenum, foam FEP insulation, Duofoil® (100% coverage) + TC braid shield (95% coverage), Flamarrest® jacket.

Insulation:
• Material: FFEP - Foam Fluorinated Ethylene Propylene
• Dia. (in.): 0.170

Outer Jacket:
• Trade Name: Flamarrest®
• Material:FEP - Fluorinated Ethylene Propylene

Mechnical Characteristics (Overall):
• Operating Temperature Range: -20°C To +75°C
• Bulk Cable Weight: 41 lbs/1000 ft.
• Max. Recommended Pulling Tension: 141 lbs.
• Min. Bend Radius/Minor Axis: 2.300 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards & Environmental Programs:
• NEC/(UL) Specification: CATVP, CMP
• CEC/C(UL) Specification: CMP
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: No
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire & Cable): Yes
• MII Order #39 (China RoHS): Yes
• Series Type: Series 6

Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 75
• Nom. Inductance (μH/ft): 0.09
• Nom. Capacitance Conductor to Shield (pF/ft): 16.5
• Nominal Velocity of Propagation VP (%): 82
• Nominal Delay (ns/ft): 1.24
• Nom. Conductor DCR @ 20°C (Ohm/1000 ft): 28.0
• Nom. Outer Shield DCR @ 20°C (Ohm/1000 ft): 1.7
• Max.Operating Voltage - UL: 300 V RMS

Flame Test:
• UL Flame Test: NFPA 262
• CSA Flame Test: FT6

Plenum/Non-Plenum:
• Plenum (Y/N): Yes
• Plenum Number: 87120, 89120

Benefits:
• All cables rated to 1 GHz
• Crush resistant dielectric material
• Corrosion resistant center conductor

Features:
• Shield options: dual shield (60% braid), tri-shield (77%), or quad shield (60%/40%)
• Indoor (CM, CMR, CMP), messengered and burial versions
• Meets or exceeds applicable ANSI/SCTE standards for drop coaxial cable

technical specification
awg 18
# coax 1
stranding solid
number of conductors 1
conductor material Bare Copper Covered Steel
dia.(in.) 0.040
outer shield - type Tape
outer shield - material Aluminum Foil-Polyester Tape-Aluminum Foil
oveall cable - nominal dia.(in.) 0.234
belden cable part number 82120

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question