Prysmian and Draka Cable 646 MCM Bostrig Type P Single Conductor Unarmored 2000V Power Cable 026021

Prysmian and Draka Cable 646 MCM Bostrig Type P Single Conductor Unarmored 2000V Power Cable 026021

Select gauge from drop-down menu for prices:

Prysmian and Draka Cable 646 MCM Bostrig Type P Single Conductor Unarmored 2000V Power Cable 026021
Prysmian and Draka Cable 646 MCM Bostrig Type P Single Conductor Unarmored 2000V Power Cable 026021

Conductor: Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor

Insulation: Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. Thickness as shown in tables on opposite page

Applications
• Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities
• Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored & sheathed). 
• The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3).
• This product may be manufactured in an unarmored or armored and sheathed version.

Approvals
• IEEE 1580 and IEEE 45- Marine Shipboard Cable
• UL 1309- Marine Shipboard Cable Type X110
• CSA 22.2 No. 245- Marine Shipboard Cable Type X110
• CSA 22.2 No. 230 as Type TC (#4/0 AWG and larger)
• Det Norske Veritas (DNV)
• American Bureau of Shipping (ABS)
• Transport Canada Approved AMS400-20-2
• Transport Canada 8700-20-2
• Lloyd’s Register of Shipping (LRS)
• United States Coast Guard-46CFR

Features/Ratings
• Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
• High strand count conductors provide superior flexibility
• Higher allowable conductor operating temperature results in increased ampacity
• Cold bend/ cold impact of -40°/ -35°C in accordance with CSA 22.2 No. 0.3
• Flame retardant in accordance with IEEE 1202 and IEC 60332-3-22 Category A
• Unarmored cables suitable for Class 1, Division 2 and Zone 2 hazardous locations offshore

Technical Specification
Conductor Size AWG/MCM 646
Conductor Size mm² 327.5
Type Designation SP2KV(HD)-646
Sheath Thicknessin 0.120
Sheath Thickness mm 3.0
Cable Diameter (nominal) in 1.260
Cable Diameter (nominal) mm 32.0
Impedance (phase-neutral) ω/kft 0.04
Impedance (phase-neutral) ω/km 0.1
Inductance mh/kft 0.10
Inductance mh/km 0.3
Capacitance pf/ft 216
Capacitance pf/m 708
Calculated Ampacity (measured @ ºc)95 670
Calculated Ampacity (measured @ ºc) 100 731
Calculated Ampacity (measured @ ºc)110 783
Calculated Ampacity (measured @ ºc)125* 979
Cable Weight (approximate) lbs/mft 2,410
Cable Weight (approximate) kg/km 3,585
Prysmian and Draka Cable Part Number 026021