Home
/
Aluminum XLPE USE-2 RHH RHW-2 Cable 600V
/
750 MCM Aluminum RHH/RHW-2 XLP USE-2 Direct Burial
1
/
of
1
750 MCM Aluminum RHH/RHW-2 XLP USE-2 Direct Burial
750 MCM Aluminum RHH/RHW-2 XLP USE-2 Direct Burial
SKU: SKU: NES4204X Download PDF
Select a gauge:
- 750 MCM Aluminum RHH/RHW-2 XLP USE-2 Direct Burial
- 750 MCM Aluminum RHH/RHW-2 XLP USE-2 Direct Burial
- 8 AWG Aluminum RHH/RHW-2 XLP USE-2 Direct Burial
- 6 AWG Aluminum RHH/RHW-2 XLP USE-2 Direct Burial
- 3 AWG Aluminum RHH/RHW-2 XLP USE-2 Direct Burial
- 4 AWG Aluminum RHH/RHW-2 XLP USE-2 Direct Burial
- 2 AWG Aluminum RHH/RHW-2 XLP USE-2 Direct Burial
- 1 AWG Aluminum RHH/RHW-2 XLP USE-2 Direct Burial
- 1/0 AWG Aluminum RHH/RHW-2 XLP USE-2 Direct Burial
- 2/0 AWG Aluminum RHH/RHW-2 XLP USE-2 Direct Burial
- 3/0 AWG Aluminum RHH/RHW-2 XLP USE-2 Direct Burial
- 4/0 AWG Aluminum RHH/RHW-2 XLP USE-2 Direct Burial
- 250 MCM Aluminum RHH/RHW-2 XLP USE-2 Direct Burial
- 300 MCM Aluminum RHH/RHW-2 XLP USE-2 Direct Burial
- 350 MCM Aluminum RHH/RHW-2 XLP USE-2 Direct Burial
- 400 MCM Aluminum RHH/RHW-2 XLP USE-2 Direct Burial
- 500 MCM Aluminum RHH/RHW-2 XLP USE-2 Direct Burial
- 1000 MCM Aluminum RHH/RHW-2 XLP USE-2 Direct Burial
- 700 MCM Aluminum RHH/RHW-2 XLP USE-2 Direct Burial
Length:
FT
Enter footage in the box - Cut to one length. Min 1 ft - Max 10000 ft.
Unit price
/
per
Sold out
Shipping calculated at checkout.
IN STOCK Shipping Available
Free shipping on orders above $1000. *Wires and cables only.
Couldn't load pickup availability

Product Information
Also Known As:
750 mcm wire, 750 mcm aluminum wire, 750 mcm wire size, rhh wire, rhh cable, bury cable, direct burial electrical cable, direct burial mc cable.
Conductors:
Compact bare 8000 series aluminum, with Class B stranding per ASTM.
Insulation:
Abrasion, heat and moisture resistant cross-linked polyethylene insulation (XLP)
|
Compatible with Manufacturer |
|
| Houston Wire : |
Black : HW003A75001 |
| Priority Wire & Cable : |
Black : 750-01XL-USE-2-ALUM |
| Southwire : |
Black : 27295501 |
Resources
Applications
USE-2 cables are power distribution cables for service entrance below ground and direct burial, as well as raceways. The electrical cable is approved according to the National Electric Code, except for the use in cable trays. The maximum operating temperature for this electrical cable is 90°C in wet and dry locations. The voltage rating is 600 volts.
Features
Standards:
• UL 44
• UL 854
• NEMA WC 70/ICEA S-95-658
• Requirements of the National Electrical Code
• ASTM B800, B801, B836
• Sunlight resistant
• Oil Resistant PRI/PRII
• Gas and Oil Res GRI/GRII
• RUS ACCEPTED
Allowable Ampacity for 750 MCM ALUMINUM RHH/RHW-2 XLP USE-2 DIRECT BURIAL: 480 Amps
• UL 44
• UL 854
• NEMA WC 70/ICEA S-95-658
• Requirements of the National Electrical Code
• ASTM B800, B801, B836
• Sunlight resistant
• Oil Resistant PRI/PRII
• Gas and Oil Res GRI/GRII
• RUS ACCEPTED
Allowable Ampacity for 750 MCM ALUMINUM RHH/RHW-2 XLP USE-2 DIRECT BURIAL: 480 Amps
Specifications
• Gauge: 750
• Stranding: 58
• Conductor Diameter Inches: 0.909
• Insulation Thickness Inches: 0.110
• O.D. Inches: 1.131
• New Weight lb/1000FT: 881 lbs
• Ampacity at 30°C: 480 Amps
• Stranding: 58
• Conductor Diameter Inches: 0.909
• Insulation Thickness Inches: 0.110
• O.D. Inches: 1.131
• New Weight lb/1000FT: 881 lbs
• Ampacity at 30°C: 480 Amps