Product Information
Stranded copper conductors tin-coated sizes 14 and smaller, uncoated for sizes 12 and larger, ethylene propylene rubber or cross-linked polyethylene insulation. Identification Code by Method3. Two, three or four conductors, as required, cabled with fillers, braided tin coated copper shield, binder tape, cross-linked polyolefin jacket, surface marking. LS2SJA, LS3SJA, LS4SJA: same, braided aluminum armor, paint.
| technical specifications: | |
| conductor size : awg or mcm | 12 |
| number of conductors in cable | 3 |
| cable type designation | ls3sj-12 |
| area of each conductor (mcm) | 6.530 |
| cable** overall diameter max. (inch) | .455 |
| cable weight per ft. appox. (lbs) | .170 |
| radius of bend min. (inch) | 2.5 |
| cdr id | std-3 |
| rated voltage max (rms) | 600 |
| ampacity, each conductor (amps,max) - dc or 60 hz - 40°c ambient | 21 |
| ampacity, each conductor (amps,max) - dc or 60 hz - 50°c ambient | 15 |
| ampacity, each conductor (amps,max) - 400 hz - 40°c ambient | 21 |
| ampacity, each conductor (amps,max) - 400 hz - 50°c ambient | 15 |
| nsn | 6145-01-202-7752 |
| seacoast military part number | mil-c-24643/43-15uo |