Conductor: Class B Compressed concentric strand soft drawn annealed copper or Class B Compact Series 8000 Aluminum per ASTM.

Insulation: High dielectric strength crosslinked polyethylene insulation to ICEA S-95-658/NEMA WC70 and UL Standard 44 for type XHHW-2. 

Grounding Conducctors: Bare stranded copper conductor per UL, ICEA, and ASTM. 

Assembly: Phase identified conductors cabled with fillers and a grounding conductor, forming a firm and cylindrical cable core.

Mechanical Protection: High strength and high crush resistant Air Bag™ layer extruded over the core assembly. 

Chemical Protection: A layer of Drylam™ which consists of aluminum tape acting as a moisture barrier & a chemical resistant extruded polymer layer. 

Jacket: Sunlight and moisture resistant polyvinyl chloride (PVC) jacket. 

Description:
Three or four conductor cable with stranded copper or aluminum conductors, extrude insulation system consisting of high dielectric strength crosslinked polyethylene, cabled with fillers and grounding conductors, foamed polymeric layer for superior mechanical protection, longitudinally applied aluminum tape bonded to an extruded oil and hydrocarbon resistant polymeric layer, and overall moisture and sunlight resistant black PVC jacket. Suitable for Class I Division2 locations.

Specifications and Ratings:
• ICEA S-95-658/NEMA WC 70 UL 44
• For CT USE Direct Buried Sunlight Resistant ER "Exposed Run” Rated Single Conductors Rated XHHW-2 
• IEEE IEEE 383 Flame Test 
• For 90°C continuous use in wet or dry conditions. 

Options: 
• Colored jacket
• Low Smoke Halogen Jacket 
• Compact Conductors

technical specification:
conductor 12 awg cu
insulation thickness (mils) 30
ground wires (no) 3
ground wires (size) 16 awg
conductor diamete (in) - (a) 0.089
insulation diameter (in) - (b) 0.16
overall jacket diameter (in) -(c) 0.62
cable weight (lbs/kft) 302
minimum bending radius (in) 5
† ampacity (amps) - (‡90°c) 30
† † impedance (micro-ohms/foot) - (pos/neg seq) 2076 + j35
prysmian cable part number -