General Cable Power Cable 250MCM 4 Conductors with Ground 600V VW-1 UL Type TC-ER ULTROL® 60+

General Cable Power Cable 250MCM 4 Conductors with Ground 600V VW-1 UL Type TC-ER ULTROL® 60+

Select gauge from drop-down menu for prices:

General Cable Power Cable 250MCM 4 Conductors with Ground 600V VW-1 UL Type TC-ER ULTROL® 60+

Conductor: 8 AWG thru 750 kcmil tinned annealed copper per ASTM B33; Class B stranding per ASTM B8

Insulation: 
• Flame-retardant, heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE) 
• Color code: Per ICEA Method 1, Table E-1

Grounding Conductor: Tinned annealed copper Class B stranding, sized according to NEC® requirements

Jacket: Flame-retardant, moisture-, oil-, sunlightand radiation-resistant thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) — Black 

Options: 
• Conductor stranding 
• ISO Metric conductors 
• Colored insulation 
• Method 4 color code 
• Sectioned grounding conductors 
• Longitudinal corrugated tinned copper tape shield 

Applications: 
• ULTROL® 60+ power cable is a 600 V multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating     stations and where flame retardancy is critical 
• For use in Class 1E power distribution and control circuits for power lighting, control and signal circuits 
• Can be installed in trays, conduit, ducts, or in direct burial applications 

Features: 
• Rated at 90?C wet or dry 
• Fully traceable 
• Qualified for 60-year service life 
• Gamma and beta radiation resistant (up to 350 megarads) 
• Submergence operability 
• Long-term thermal endurance and superior electricals
• Excellent mechanical cut-through properties 
• Long-term moisture and radiation stability 
• Free stripping for ease of termination 
• Meets cold bend test at -40°C 

Industry Compliances: 
• Class 1E Qualified in accordance with IEEE 323-1974/2003 and IEEE 383-1974/2003 
• ICEA S-73-532 
• UL 1277 Type TC-ER 
• UL 44 XHHW-2 

Flame Test Compliances: 
• IEEE 383:1974 
• IEEE 383:2003 
• ICEA T-29-520 
• IEEE 1202/FT4-1991, Aged & Unaged 
• VW-1 

Other: 
• Quality assurance program in accordance with NRC 10CFR50 Appendix B 
• ANSI N45.2 
• ASME NQA-1 
• NIAC 
• NUPIC 

Packaging: Material to be shipped on spools on nonreturnable wooden reels

technical specifications:
cond.size(awg/kcmil) 250
no. of cond. 4
cond.strand 37/.0822
minimum avg.insulation thickness(inches) 0.065
minimum avg.insulation thickness(mm) 1.65
ground wire size(awg) 4
minimum avg.jacket thickness(inches) 0.110
minimum avg.jacket thickness(mm)
2.79
nominal cable o.d.(inches) 1.898
nominal cable o.d.(mm) 48.2
copper weight(lbs/1000 ft) 3239
copper weight(kg/km) 4820
net weight(lbs/1000 ft) 4189
net weight(kg/km) 6233
catalog number 32560.250.4

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question