General Cable Polyrad® 3 x 35 CSA LSHF Low-Smoke Halogen-Free Medium Wall Multi-Core Unscreened and Sheathed EN Cable Reduced Dimensions 0,6/1kV

General Cable Polyrad® 3 x 35 CSA LSHF Low-Smoke Halogen-Free Medium Wall Multi-Core Unscreened and Sheathed EN Cable Reduced Dimensions 0,6/1kV

SKU: SKU:

gauge:
  • General Cable Polyrad® 3 x 35 CSA LSHF Low-Smoke Halogen-Free Medium Wall Multi-Core Unscreened and Sheathed EN Cable Reduced Dimensions 0,6/1kV
FT
Enter footage in the box - Cut to one length. Min 1 ft - Max 10000 ft.
Sold out
Shipping Available
Free shipping on orders above $1000.* Only on standard purchases of cables and wires.
View full details
Product Information

*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color

Polyrad 3 x 35 CSA LSHF Low-Smoke Halogen-Free Medium Wall Multi-Core Unscreened and Sheathed EN Cable Reduced Dimensions 300V/500V

Conductor: Flexible Class 5 stranded tinned copper per IEC 60228

Insulation:
• 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin (EI 106 to EI 109)
• Black with printed numbers – unless otherwise specified

Sheath:
• 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin (EM 101 to EM 104)
• Black – unless otherwise specified

Cable Markings:
• Manufacturer’s Name
• EN Reference
• Voltage Rating (U0)
• Number of Cores and Conductor Size
• Insulation/Sheath Code Designation per Annex A of EN 50264-3-2
• Lot Number

Applications:
300 V/500 V
• Internal safe circuits
• Control and monitoring circuits
0,6/1 kV
• Lighting circuits
• Auxiliary and electric heating circuits
• Control and monitoring circuits

Tested in Accordance with:
• EN 60684-2: No Fluorine
• EN 50305/EN 60811-2-2: Resistant to Oil and Fuel
• EN 60811-2-1: Resistant to Mineral Oil
• EN 50305: Ozone-Resistant; No Toxicity
• EN 60811-1-4: Cold Bend (-40?C)

Other Design Adherence:
• EN 60332-1-2 and EN 60332-3-25: Flame- & Fire-Retardant
• EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases
• EN 61034-2: Low-Smoke
• No SVHC Listed Chemicals under REACH
• RoHS Compliant

technical specifications:
cross-sectional area (n x mm²) 3 x 35
conductor diameter (mm) 8.12
mean thickness of insulation (mm) 0.9
core diameter (min. in mm) 9.0
core diameter (max. in mm) 10.6
mean thickness of sheath (mm) 1.2
cable diameter (min. in mm) 23.0
cable diameter (max. in mm) 28.2
weight (cable in kg/km) 1160
part number 413780