The GMDSS front panel for Mass 24/50-2 includes a digital volt and ampere meter, designed for professional use It features a front display equipped with GMDSS alarm functions GMDSS, which stands for Global Maritime Distress and Safety System, consists of internationally agreed-upon safety procedures and communication protocols mandated by the SOLAS convention, utilizing DSC and satellite communication.

The digital panel effectively displays battery voltage and current.

Features and Benefits:

    •GMDSS alarm functions for enhanced safety.

    •Digital display for easy monitoring of battery status.

    •Automatic detection of 12 V or 24 V systems.

    •Potential-free switch contacts for various alarms.

    •Monitoring the status of battery and battery charger in marine applications.

    •Used in compliance with SOLAS regulations.

Specifications:

 Function monitoring of the status of the battery and battery charger (12/24 V DC)
 Supply voltage 8-32 V DC
 Safe compass distance standard 1 meter; steering: 0.3 mm
 Display/read-out LCD display and status LED’s for DC voltage alarm, charger alarm and AC mains alarm
 Current 110 mA (12 V) / 65 mA (24 V), normal operation mode without activated relays. Current accuracy: ± 2 A (< 45 A), ± 4 A (> 45 A)
 Alarms potential-free switch over contacts for DC voltage alarm, charger alarm and AC mains alarm. Max. switching current: 1 A
 Dimensions to be integrated in the battery charger
 Dimensions shunt, hxwxd M8, 84 x 44 x 44 mm
 Voltage range 0 - 62.7 V DC (0.1 V resolution); a 12 V or 24 V system is detected automatically
 Voltage accuracy ± 0.2 V (12 V), ± 0.4V (24 V)
 Shunt specification 500 Amp / 50 mV (included with the delivery)
 Current measurement range -500 … 500 A

 