Skip to product information
1 of 1

Interlocked Armor Control Cable - 14 Gauge - 15 Conductor - 600 Volt UL Type MC

Interlocked Armor Control Cable - 14 Gauge - 15 Conductor - 600 Volt UL Type MC

SKU: SKU:  

Select a gauge:
  • Interlocked Armor Control Cable - 14 Gauge - 15 Conductor - 600 Volt UL Type MC
Length: FT
Enter footage in the box - Cut to one length. Min 1 ft - Max 10000 ft.
Sold out
Shipping calculated at checkout.
Shipping Available
Free shipping on orders above $1000. *Wires and cables only.
View full details
Product Information

*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color

Untitled Document
Technical Specifications:
Size (AWG or kcmil): 14
No. of Conductors 15
Net Weight: 550
Overall Diameter (Inches): 0.95
Insulation Thickness (Mils): 30
Jacket Thickness (Mils): 50
No. of Strands: 7
Class 1 Div.2 Connector No.: 424CU04
Rain Tight Connector No.: 416MC04

Specifications:

  • Interlocked Armor - Control Cable
  • 600 Volt UL Type MC, CT Use, 90°C
  • XLP VW-1 XHHW-2 Insulation
  • Aluminum Armor
  • Copper Conductors

Application:
For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.

Conductors:
Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).

Insulation:
Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.

Grounding Conductor:
Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.

Armor:
Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.

Jacket:
Black sunlight-resistant PVC per UL Standard 1569.

Flame Tests:
UL 1581 70,000 BTU/hr flame test

Color Code:
ICEA Method 1, Table E-2

Connectors:
Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components Rain Tight: 416MC series – all nickel-plated brass