Helukabel 24 AWG 12 Cores TRONIC LiYY Flexible Colour Coded To DIN 47100 Meter Marking Cable 18037

Helukabel 24 AWG 12 Cores TRONIC LiYY Flexible Colour Coded To DIN 47100 Meter Marking Cable 18037

Select gauge from drop-down menu for prices:

Helukabel 24 AWG 12 Cores TRONIC LiYY Flexible Colour Coded To DIN 47100 Meter Marking Cable 18037
Helukabel 24 AWG 12 Cores TRONIC LiYY Flexible Colour Coded To DIN 47100 Meter Marking Cable 18037

Technical data: 
• Special-PVC data cables adapted to DIN VDE 0812 

Temperature range: 
• Flexing -5°C to +80°C 
• Fixed installation -40°C to +80°C 

Operating peak voltage: 
• Not for purposes of high current and power installation, 0,14 mm² = 350 V ≥ 0,25 mm² = 500 V 

Test voltage: 
• Up to 0,25 mm² 1200 V 
• From 0,34 mm² 2000 V 

Breakdown voltage: 
• Up to 0,25 mm² 2400 V 
• From 0,34 mm² 4000 V 

Insulation resistance: 
• Min. 20 MOhm x km 

Capacitance: 
• Approx.-value at 800 Hz 
• 0,14 mm² 120 pF/m 
• 0,25 mm² 150 pF/m 

Inductance: 
• Approx. 0,65 mH/km 

Impedance: 
• Approx. 78 Ohm 

Minimum bending radius: 
• Flexing 7,5x cable Ø 
• Fixed installation 4x cable Ø 

Radiation resistance: 
• Up to 80x106 cJ/kg (up to 80 Mrad) 

Cable structure: 
• Bare copper-conductor, from 0,5 mm² to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5 
• Conductor construction: 0,14 mm² = 18x0,1 mm, 0,25 mm² = 14x0,15 mm, 0,34 mm² = 7x0,25 mm&nbs
• Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 / DIN EN 50363-3 
• Core identification to DIN 47100, without colour repetition 
• Cores stranded in layers with optimal lay-length 
• Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1/DIN EN 50363-4-1 
• Sheath colour grey (RAL 7001) 
• with meter marking 

Properties: 
• Extensively oil resistant, oil-/ chemical Resistance - see table Technical Informations 
• The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers 

Tests: 
• PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B) 

Note: 
• Also available in paired version, see HELUKABEL®-PAAR-TRONIC 
• AWG sizes are approximate equivalent values. The actual cross-section is in mm². 
• Screened analogue type: TRONIC-CY (LiY-CY) 

Application: 
• These cables are used for flexible use with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air, wherever the construction requirements call for a minimum outer diameter, TRONIC is the suitable cable to use. This applies especially to such areas as tool making and machine industries as well as electronic, computer, measurement and control sectors. = The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

technical specification:
awg-no. 24
no.cores x cross-sec. mm² 12 x 0,25
outer ø app. mm
7,0
cop. weight kg/km 28,8
weight app. kg/km 66,0
helukabel part number 18037

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question