Skip to product information
1 of 1

Belden 29512 12 AWG 3 Conductor 65x30 Stranding 1000V Variable Frequency Drives Cable

Belden 29512 12 AWG 3 Conductor 65x30 Stranding 1000V Variable Frequency Drives Cable

SKU: SKU: NES29512   Download PDF

Length: FT
Enter footage in the box - Cut to one length. Min 1 ft - Max 10000 ft.
Regular price Now $15.29 /FT   Web pricing policy
Regular price BEFORE   Sale price Now $15.29 /FT Web pricing policy
Sold out
Shipping calculated at checkout.
IN STOCK
Shipping Available
Free shipping on orders above $1000. *Wires and cables only.
View full details
Product Information

Belden 29512 12 AWG 3 Conductor 65x30 Stranding 1000V Variable Frequency Drives Cable

Description:

Belden 300% Ground Flexible VFD, 3 Conductor 12AWG (65x30) Tinned Copper, XLPE Insulation M4 Color Code+PVC Insulated Ground, Overall Beldfoil+Tinned Copper Braid(85%) Shield, 1 Pair 16AWG (26x30) Tinned Copper XLPE Beldfoil, Black PVC Outer Jacket, 600V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable 1000V CSA AWM I/II A/B 600V CIC TC SUN RES DIR BUR Oil Resistant Shielded Pair is Outside the Power Group Braid Shield for Isolation.

Insulation:

Element: Conductor(s):-

Material: XLPE - Cross-Linked Polyethylene (Thermoset)
Nom. Thickness: 0.046 in (1.2 mm)
Nom. Insulation Diameter: 0.187 in (4.75 mm)

Element: Pair(s):-
Material: XLPO - Crosslink Polyolefin 
Nom. Thickness: 0.032 in (0.81 mm)
Nom. Insulation Diameter: 0.123 in (3.12 mm)

Element: Ground Wire:-
Material: PVC - Polyvinyl Chloride
Nom. Thickness: 0.047 in (1.2 mm) 
Nom. Insulation Diameter: 0.187 in (4.75 mm)

Inner Shield:

• Element: Pair(s)
• Shield Type: Tape
• Material: Bi-Laminate (Alum+Poly)
• Coverage: 100% 
• Drainwire Type: 18 AWG (19x30) TC
• Foil-In, Shorting fold

Outer Shield:

• Shield Type Tape, Tri-Laminate (Alum+Poly+Alum) Material, Coverage 100%, Drainwire Type 12 AWG (65x30) TC

• Shield Type Braid, Tinned Copper (TC) Material, Coverage 85%

• Foil+braid shield on power conductors & Ground only; extra pair has own foil shield.

Outer Jacket:

Material: PVC - Polyvinyl Chloride
Nom. Thickness: 0.080 in (2.0 mm)
Nom. Diameter: 0.895 in (22.7 mm)
Overall Cable Diameter (Nominal): 0.895 in (22.7 mm)
Polyester Tape

Applications:

Variable Frequency Drives (VFD); AC Motor and Drive Systems; Class 1 Division 2 Hazardous Locations

Specifications:

Element: Conductor(s):-
Size (AWG): 
12
• No. of Conductor3
Stranding:
65x30 
• Conductor Material:
TC - Tinned Copper

Element: Pair(s):-
• Size (AWG):
16
• No. of Elements:
1
• Stranding: 
26x30
• Conductor Material:
TC - Tinned Copper

Element: Ground Wire:-
• Size (AWG):
12
• No. of Elements:
1
• Stranding:
65x30 
• Conductor Material:
TC - Tinned Copper

Part Number:
29512

Resources

Reviews