Conductors: Flexible tinned copper

Ground Check Conductor: Flexible tinned copper with yellow polypropylene insulation

Insulation Shielding: Tinned copper and color coded nylon braid

Strand Shield: Semi-conducting layer

Ground Wires: Flexible tinned copper

Insulation: 90°C ethylene-propylene rubber (EPR)

Insulation Shielding: Semi-conducting tape

Assembly: Taped core

Jacket: Reinforced mold-cured thermosetting Chlorinated Polyethylene (CPE) Jacket. Cable identification via permanent marking.

Application:
• Heavy duty high voltage portable power cable for use in circuits not exceeding the rated voltage. These cables are used for heavy mobile equipment such as drag lines, shovels, dredges, drills and for power feeders. Recommended maximum continuous conductor temperature in 90°C. Suitable for shallow water submersion.
• Cable carries “P-184-MSHA” marking indicating acceptance as flame resistant by the Pennsylvania Department of Environmental Protection and the Mine Safety and Health Administration.
• Tiger® Brand Mining Cable meets or exceeds ICEA Standards S-75-381/NEMA WC-58, ASTM B-172 and B-33.

Ratings & Approvals:
• Mine Safety & Health Administration 184-MSHA.
• Pennsylvania Department of Environmental Protection P-184.
• Insulated Cable Engineers Association S-75-381/NEMA WC-58. Design standard for mining cables
• Canadian Standards Association C22.2 No. 96 File 82346, FT1, FT5, -50°C CSA Phase Color ID available on MTO Type SHD-GC, SHD-BGC up to 25kV SHD-GC meets FT4 requirements

technical specification:
power conductors(size awg) 250
power conductors(no. of wires per conductor) 627
power conductors(insulation thickness mils) 210
grounding conductors(size awg) 1/0
grounding conductors(no. of wires per conductor) 266
jacket thickness mils 265
nominal outside dimensions in. 3.15
approx. weight lbs. per 1,000 ft. 6960
ampacity* 40°c ambient temp 359
amercable and tiger brand part number 36-519-250