750MCM 15kV EPR-PVC MV-105 Shielded

750MCM 15kV EPR-PVC MV-105 Shielded

Product Details

Applications:  EPR-PVC- 15KV Shielded, Ungrounded Type MV105 Power Cable is for use in airborne, direct entombment, link plate, raceway, and underground pipe establishments as allowed by the National Electrical Code. These links are equipped for working consistently at a conductor temperature not in excess of 105°C for typical operation, 140°C for crisis over-burden conditions, and 250°C for short circuit conditions, and are appraised at 15,000V, 133% protection level (ungrounded framework). For use in Class I, Div II areas. Most extreme sidewall weight is 1000 lbs. This link can be introduced without the requirement for pulling oil.  EPR-PVC- 15KV Shielded, Ungrounded Type MV105 Power Cable is planned for use as a feeder and can be utilized as a part of a wide range of sorts of uses where greatest conveying limit is required. The link can be introduced in channel, pipe or aeronautical applications and must be upheld by an emissary wire. This link can likewise be covered specifically. The link can work in wet or dry areas and has a most extreme conductor temperature of 105°C. This link is considered satisfactory by Underwriters Laboratories details and the Occupational Safety and Health Administration (OSHA).

Search Terms: 750MCM cable, 750MCM 15KV EPR-PVC MV-105 Shielded

EPR-PVC, Shielded Cable, Underground Cable, Medium Voltage Cable, MV105, MV-105, Power Cable, Feeder Cable, 15kv Wire, 15kv Cable, Heat-resistant cable, heat resistant cable, direct burial cable, aerial cable, overhead cable, underground cable, Easy pull cable

Colors: Offered in black, white, red, orange, gray, yellow, green, blue. Striped pattern available in all colors.  Standard is black.

Regulations:
UL 1072- These requirements cover the shielded and nonshielded medium-voltage power cables that are described in Tables 1.1 (single-conductor) and 1.2 (multiple-conductor). 
CSA C68.10 - A CSA specification for industrial electrical cables. 

CSA FT4 - 70,000 BTU flame test for cables used in trays should burn the cables for 20 minutes and not exceed 1.5 meters after the test is finished. 

IEEE 383 - Standard for qualifying electric cables and splices for nuclear facilities. 

Jacket: Polyvinyl choloride (PVC) jacket is fire-resistant, and impervious to daylight and wetness. 

Insulation: Ethylene propylene rubber (EPR).

Conductor: 100% annealed uncoated copper compact stranded.

Technical Specifications:
Size AWG: 750
Stranding: 61
Diameter Complete Cable (O.D.) (Inches): 1.840
Weight Per 1000ft Total (Lbs.): 3445
Allowable Ampacity in Ducts (Amps): 565
General Cable Part # 17031.13701
Omni Cable Part # MVE375001
Southwire item Part # 956052

 

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question