600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 01404

600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 01404

Select gauge from drop-down menu for prices:

600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 01404
600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 01404
Technical Specifications:
Catalog Number HW307 01404
Size AWG/kcmil 14
No. of Conductors 4
No. of Strands 7
Insulation Thickness Mils 30
Jacket Thickness Mils 50
Ground Wire Size No.-AWG 2-16
Class 1 Div. 2 Connector No. 424MA02
Rain Tight Connector No. 416MC02
Armor Diameter Inch 0.48
Overall Diameter Inch 0.59
Net Weight Lbs/Mft 195

Specifications:

  • Impervious Continuously Welded Armor - Power and Control Cable
  • 600 Volt UL Type MC-HL, CT Use, 90°C
  • XLP XHHW-2 Insulation
  • Aluminum Armor
  • Copper Conductors

Application:
For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. UL listed, Type MC-HL per UL Standard 2225 for use in Class I, Division I hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded and corrugated aluminum armor cable is recommended as an economical alternative to wire in conduit systems.

Conductors:
Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).

Insulation:
Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.

Grounding Conductor: Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with NEC requirements.

Armor:
Impervious continuously welded and corrugated aluminum.

Jacket:
Black flame-retardant and sunlight-resistant PVC.

Flame Tests:

  • UL 1581 70,000 BTU/hr flame test
  • ICEA 70,000 BTU/hr and 210,000 BTU/hr flame test
  • IEEE 383 70,000 BTU/hr flame test

Color Code:

  • 14 AWG - 10 AWG: ICEA Method 1, Table E-2
  • 8 AWG - 750 kcmil: ICEA Method 4

Additional Standards:

  • UL listed Type CWCMC to IEEE 45/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.
  • Meets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test.

Connectors:

  • Explosion Proof, Class I Division 1: 424MA series – all nickel-plated aluminum
  • Rain Tight: 416MC series – all nickel-plated brass

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question