4/0-3 W/GRND EPR-HYP Tray Cable

4/0-3 W/GRND EPR-HYP Tray Cable

4/0-3 W/GRND EPR-HYP Tray Cable

EPR-HYP Power Cable-3 Conductor w Ground Type TC

Product Description:

This cable gets its name from the ethylene propylene rubber insulation which provides protection for the conductors without compromising the cable’s flexibility and maneuverability.  The multi-conductor cable contains three individually insulated copper conductors and one bare copper ground wire.  The cable assembly is wrapped in a clear separator, making the cables easy to strip if necessary.  The outer layer is a Hypalon® jacket, resistant to sunlight, high heat, fire, water and abrasion.  The cable can carry a maximum ampacity of 600 volts.

Applications:

ERP-HYP Power Cable is suitable for a variety of heavy duty tasks.  The cable can be installed in duct or with approval, can be buried directly.  It can also be strung aerially with support from a messenger wire.   Its ability to handle rough conditions makes it a favorite for use in hazardous locations.  This cable can be found in utility substations and generating stations as well as in industrial buildings, mills, factories, and chemical plants.  The product is also suitable for residential and commercial use.

Specifications:

  • In accordance with specifications set forth by the American Society of Testing and Materials, this cable is in alignment with ASTM Standard B-189 which sets specifications for lead-coated copper wiring.  The specifications measure the conductor’s tensile strength, elongation, and resistivity.
  • The cable also adheres to regulations set forth by Underwriters Laboratories, a compliance and regulations organization, UL Standard 44 which sets regulations for thermoset conductors.  This standard states that thermoset conductors must be able to tolerate high temperatures as well as be able to function in wet or dry locations. 
  • The product meets specifications for UL 1277, which measures a wire’s ability to resist fire. 
  • The cable passes IEEE Flame Test of 70,000 BTU and also passes the 210,000 BTU Flame Test.

Construction: 

  • Conductors

-           The three phase conductors are ASTM Class B-189 annealed copper cables.  This particular type of copper coating is flexible and lasts extremely long.

  • Ground Conductor

-           The assembly contains one bare copper ground conductor.  The ground conductor’s purpose is to ensure steady conductivity through the phase conductors.

  • Insulation

-           The ethylene propylene insulation protects each conductors electrical components, keeping them safe from corrosive liquids and gasses., 

  • Outer Jacket

-           The Hypalon® jacket on this cable makes the cable easy to install while adding long lasting protection to the conductors.  The smooth, flexible exterior makes it easy to pull through walls and maneuver around corners.  Once in place, the jacketing serves as the first line of defense against abrasion and corrosion.

Technical Specifications:
Name: EPR-HYP 4/0 Gauge
Number of Conductors in Cable: 3
Ground Wire Size (AWG): 4
Size AWG: 4/0
Stranding: 19
Diameter Complete Cable (O.D.) (Inches): 1.570
Weight Per 1000ft Total (Lbs.): 2548