Prysmian Cable 600 Volt USEB90 Low Voltage Utility Cables

Collection: Prysmian Cable 600 Volt USEB90 Low Voltage Utility Cables

Product Details

USEB90 Cable is made of two classes of conductors i.e. Class B conductor and the aluminum alloyed conductor. These conductors have efficient electric transmission and are also adapted to low voltage power activities. A low voltage utility cable just like the name suggests, is cable that carries low power voltage in order to run less heavy-load machines and different activities.

Choosing the right cable to serve your power line is a very important step because a part from giving you a stable power supply, it also relieves you from unnecessary expenses of inspection and replacement of blown out cables; how does this occur? Well, when you make poor cable choice it will be installed in an irrelevant power line to transmit big loads of power voltages. This would cause a major power blow leading to electric fault in your line. It is why you need a cable with adaptive features to best suit your premises like USC90 Low Voltage Cable.

Insulation
Insulation is an important aspect that should be looked at keenly when purchasing a cable of your preferred choice. It plays a major role as it keeps you safe from electric shocks as well as providing an interface boundary between the live conductors and the neutral conductors. This barrier is needed since it prevents electric blows. USC90 Low Voltage Cable is insulated with cross linked polyethylene which has high dielectric strength and well adapted to operate in low temperatures.

The outer jacketing material of USC90 Low Voltage Cable that is responsible for coating all of the conductors of this cable, is made of a polyvinyl chloride (PVC) which is a non-biodegradable material. PVC is resistant to fungus and cannot decompose even when buried underground, and a cable made of PVC automatically is more durable.

Installation
USC90 Cable can be installed in direct burial methods because of tis mechanical strength. It can as well be installed in air conduits and the installation manuals should be considered fully.

phase
conductor
insulation
thickness
(mils)
insulation
diameter
(mm)
major
dimension
(mm)
minor
dimension
(mm)
cable
weight
(kg/km)
neutral
configuration
reduced or
full neutral
† ampacity
(amps)
prysmian cable
part number
(a) (b) (c) number of wires
& size (awg)
600 volt aluminum two conductor
6 awg al 45 6.68 19.30 12.62 268 7-#18 reduced 55 Q0J94YC
6 awg al 45 6.68 19.30 12.62 304 11-#18 full 55 Q0J940C
4 awg al 45 7.80 22.56 14.76 402 11-#18 reduced 75 Q0K94YC
4 awg al 45 7.80 22.56 14.76 449 17-#18 full 75 Q0K940C
3 awg al 45 8.46 24.36 15.90 476 9-#16 reduced 85 QZ5568C
3 awg al 45 8.46 24.36 15.90 525 13-#16 full 85 QZ5589C
2 awg al 45 9.19 25.88 16.69 557 11-#16 reduced 100 Q0M94YC
2 awg al 45 9.19 25.88 16.69 630 17-#16 full 100 Q0M940C
1 awg al 45 10.54 28.58 18.03 669 13-#16 reduced 115 Q0O94YC
1 awg al 55 10.54 28.58 18.03 767 21-#16 full 115 Q0O940C
1/0 awg al 55 11.48 30.45 18.97 801 17-#16 reduced 135 Q0Q94YC
1/0 awg al 55 11.48 30.45 18.97 910 26-#16 full 135 Q0Q940C
2/0 awg al 55 12.50 32.49 19.99 958 22-#16 reduced 150 Q0R94YC
2/0 awg al 55 12.50 33.15 20.65 1108 21-#14 full 150 Q0R940C
3/0 awg al 55 13.72 34.93 21.21 1135 26-#16 reduced 175 Q0S94YC
3/0 awg al 55 13.72 35.59 21.87 1330 26-#14 full 175 Q0S940C
4/0 awg al 55 15.04 38.23 23.19 1386 21-#14 reduced 205 Q0T94YC
4/0 awg al 55 15.04 39.12 24.08 1642 21-#12 full 205 Q0T940C
250 MCM al 65 16.79 41.73 24.94 1653 26-#14 reduced 230 Q0U94YC
250 MCM al 65 16.79 42.62 25.83 1967 26-#12 full 230 Q0U940C
300 MCM al 65 18.08 46.74 28.65 2102 21-#12 reduced 260 QZ5569C
300 MCM al 65 18.08 47.80 29.72 2501 21-#10 full 260 QZ5590C
350 MCM al 65 19.23 49.02 29.79 2421 26-#12 reduced 280 Q0V94YC
350 MCM al 65 19.23 50.09 30.86 2861 25-#10 full 280 Q0V940C

25 products