Product Information
Conductors:
• 18 AWG – 10 AWG
• Stranded tinned copper(Other optional conductor materials available)
Insulating System: Extruded silicone rubber
Standard Color: Coding Available in Colors
Characteristics:
• UL VW -1 Flame rated.
• Radiation, ozone, and moisture resistant.
• Easy to strip.
• Very flexible.
• Suitable for applicati ons to -60°C.
Ratings / Approvals:
• 150°C – 15 KVDC - UL Style 3239
• 150°C – 20 KVDC - UL Style 3239 / CSA TV-20
• 150°C – 25 KVDC - UL Style 3239
• 150°C – 30 KVDC - UL Style 3239
• 150°C – 40 KVDC - UL Style 3239
| technical specification: | |
| awg. size | 12 |
| # strands | 65 |
| outer dia. inches | 0.273 |
|
outer dia. mm
|
6.93 |
| wgt - lbs per 1000 ft | 46.86 |
| wgt - kg per km | 69.74 |
| ul | 3239 |
| csa | n/a |
| radix wire part number | HRA12T065 |