Prysmian and Draka Cable Bostreel Power Reeling Cable 90C TO -40C Thermoset Jacket 5,8 and 15 KV Cable

Prysmian and Draka Cable Bostreel Power Reeling Cable 90C TO -40C Thermoset Jacket 5,8 and 15 KV Cable

Select gauge from drop-down menu for prices:

Prysmian and Draka Cable Bostreel Power Reeling Cable 90C TO -40C Thermoset Jacket 5,8 and 15 KV Cable

Product Details

Conductors / Ground / Ground Check: Extra flexible rope stranding (Class K), soft drawn uncoated copper; per ASTM B3, ASTM B172, and UL 1072 for high flexibility, extended flex-life, reduced copper fatigue/conductor breakage.

Insulation: Thermoset EPR insulation that meets and exceeds the requirements of ANSI/NEMA WC58 ICEA S-75-381 and UL 1072 for excellent physical/ electrical properties, suitable for use in extreme flexing applications. 

Shield: Conductor shield, insulation and insulation shield applied as triple extrusion. Braided copper shield applied for maximum flexibility and provides corona-free shielding method, higher conductivity and improved personnel safety. 

Cabling: Conductors are cabled without fillers or a separator allowing pressure extruded jacket to fill interstices to prohibit conductor displacement during flexing and high tension applications. 

Jacket: Black, low-temp, co-extruded, reinforced, extra heavy duty thermoset jacket which is flame, oil and sunlight resistant and is suitable for use indoors and outdoors in severe flexing applications where oil,chemicals and extreme temperatures are considerations.

 Applications:
•BOSTREEL™ ALL-TEMP Portable Power Reeling Cable is designed and manufactured for use in medium voltage reeling applications on container handling cranes, log handling cranes, stacker reclaimers, ship loaders and unloaders, and other similar material handling applications where flame, abrasion, chemicals, moisture, impact, tearing and temperature extremes are considerations. 
•BOSTREEL™ ALL-TEMP power reeling cables are manufactured to be resistant to the unique tension and torsional stresses common to high mounted cable reels and high travel speeds without compromising safe operation.

Specifications and Ratings: 
•Rated for continuous operation at
•40° C to 90° C 
•UL listed MV-90 
•CSA listed
•MSHA approved

Construction Options:Consult the factory for BOSTREEL™ cables designed and manufactured in a variety of alternative constructions for specific applications.

Options include: 
•Composite constructions incorporating optical fiber (multimode or single mode) for voice, data and video transmission. 
•Alternative jacketing materials formulated to provide superior service life in the world’s harshest environments.

power conductor Size ground conductor Size approximate cable weight
lbs/mft(kg/km)
prysmian and draka
cable part number
Action
6 awg (266/30) 8 awg (168/30) 1862 (2771) 028594 Request a Quote
4 awg (420/30) 8 awg (168/30) 2162 (3217) 028595 Request a Quote
2 awg (665/30) 6 awg (266/30) 2740 (4077) 028597 Request a Quote
1 awg (836/30) 5 awg (336/30) 3150 (4688) 028597 Request a Quote
1/0 awg (1045/30) 4 awg (420/30) 3704 (5512) 028598 Request a Quote
2/0 awg (1045/30) 3 awg (532/30) 4076 (6065) 028599 Request a Quote
3/0 awg (1672/30) 2 awg (665/30) 4667 (6945) 028600 Request a Quote
4/0 awg (2107/30) 1 awg (836/30) 5432 (8083) 028601 Request a Quote
250 mcm (2499/30) 1/0 awg (1045/30) 7049 (10490) 028602 Request a Quote
300 mcm (2989/30) 1/0 awg (1045/30) 7556 (11244) 028603 Request a Quote
350 mcm (3458/30) 2/0 awg (1330/30) 8493 (12638) 028604 Request a Quote
500 mcm (5054/30) 4/0 awg (2107/30) 11346 (16884) 028605 Request a Quote
3 Conductor / 8 Kv (100% insulation level)
4 awg (420/30) 8 awg (168/30) 2567 (3820) 028606 Request a Quote
2 awg (665/30) 6 awg (266/30) 3160 (4702) 028607 Request a Quote
1 awg (836/30) 5 awg (336/30) 3583 (5332) 028608 Request a Quote
1/0 awg (1045/30) 4 awg (420/30) 4109 (6115) 028609 Request a Quote
2/0 awg (1330/30) 3 awg (532/30) 4557 (6781) 028610 Request a Quote
3/0 awg (1672/30) 2 awg (665/30) 5166 (7688) 028611 Request a Quote
4/0 awg (2107/30) 1 awg (836/30) 6220 (9256) 028612 Request a Quote
3 Conductor / 15 Kv (100% insulation level)
4 awg (420/30) 8 awg (168/30) 3237 (4817) 028613 Request a Quote
2 awg (665/30) 6 awg (266/30) 3808 (5667) 028614 Request a Quote
1 awg (836/30) 5 awg (336/30) 4275 (6362) 028615 Request a Quote
1/0 awg (1045/30) 4 awg (420/30) 4905 (7299) 028616 Request a Quote
2/0 awg (1330/30) 3 awg (532/30) 5291 (7874) 028617 Request a Quote
3/0 awg (1672/30) 2 awg (665/30) 6046 (8997) 028618 Request a Quote
4/0 awg (2107/30) 1 awg (836/30) 7198 (10711) 028619 Request a Quote

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question