Helukabel 20 AWG 7 Cores With GN-YE Conductor F-C-PURö-JZ Tear And Coolant Resistant Cu-Screened Without Inner Sheath Cable 21205

Helukabel 20 AWG 7 Cores With GN-YE Conductor F-C-PURö-JZ Tear And Coolant Resistant Cu-Screened Without Inner Sheath Cable 21205

Select gauge from drop-down menu for prices:

Helukabel 20 AWG 7 Cores With GN-YE Conductor F-C-PURö-JZ Tear And Coolant Resistant Cu-Screened Without Inner Sheath Cable 21205

Product Details

Technical Data:
• Special-PUR control cable adapted to DIN VDE 0285-525-1 / DIN EN 50525-1

Temperature Range:
• flexing -20°C to +80°C
• fixed installation -40°C to +80°C

Nominal Voltage: U0/U 300/500 V

Test Voltage: 3000 V

Breakdown Voltage: min. 6000 V

Coupling Resistance:
• max. 250 Ohm/km

Minimum Bending Radius:
• flexing 10x cable Ø
• fixed installation 5x cable Ø

Radiation Resistance:
• up to 100x106 cJ/kg (up to 100 Mrad)

Cable Structure:
• Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5
• Core insulation of oil resistant PVC compound type TI2 adapted to DIN VDE 0207-363-3 / DIN EN 50363-3 for better sliding abilities
• Core identification to DIN VDE 0293 black cores with continuous white numbering
• GN-YE conductor, 3 cores and above in the outer layer
• Cores stranded in layers with optimal lay-length
• Separating foil
• Tinned copper braided screen, approx. 85% coverage
• Core wrapping of fleece guarantees easy cable stripping
• Outer sheath of special full-polyurethane compound type TMPU to DIN EN 50363-10-2
• Sheath colour grey (RAL 7001) also available in other colours on request
• With meter marking

Properties:
Resistant to: UV-Radiation, Oxygene, Ozone, Hydrolysis, Microbes
• The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers

Note:
• G = with green-yellow conductor x = without green-yellow conductor (OZ)
• AWG sizes are approximate equivalent values. The actual cross-section is in mm².
• Unscreened analogue type: PURö-JZ

Application:
Extremely robust control cable characterised by high abrasion and notch resistance properties. Used for critical areas in such applications as machinery, tooling and plant construction, in rolling mills and steel works because of the resistance to mineral oils and to coolant emulsions in particular. Rapid and safe installation assured by the good flexibility of the cable. Suitable for outdoor installation.
An interference-free transmission of signals and pulses is assured by the high screening density. The ideal interference-protected control cable for such applications as given above.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

technical specification:
awg-no. 20
no.cores x cross-sec. mm² 7 G 0,5
outer ø app. - mm 7,6
cop. weight - kg/km 69,0
weight app. - kg/km 97,0
helukabel part number 21205

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question