Helukabel 14 AWG 3 Cores With GN-YE Conductor H07ZZ-F Control Cross Linked Halogen-Free Cable 37204

Helukabel 14 AWG 3 Cores With GN-YE Conductor H07ZZ-F Control Cross Linked Halogen-Free Cable 37204

Select gauge from drop-down menu for prices:

Helukabel 14 AWG 3 Cores With GN-YE Conductor H07ZZ-F Control Cross Linked Halogen-Free Cable 37204
Helukabel 14 AWG 3 Cores With GN-YE Conductor H07ZZ-F Control Cross Linked Halogen-Free Cable 37204

Technical data: 
• Halogen-free cross-linked control cable to DIN VDE 0285-525-3-21 / DIN EN 50525-3-21 

Temperature range: 
• Flexing -5°C to +70°C 
• Fixed installation -20°C to +70°C 
• Permissible operating temperature at conductor +90°C 

Nominal voltage: 
• Flexing U0/U 450/750 V 
• Fixed installation U0/U 0,6/1 kV 

Test voltage:  
• 2500 V 

Permanent tensile load: 
• Max. 15 N/mm² under consideration of total copper cross-sections 

Minimum bending radius: 
• Flexing 10x cable Ø 
• For fixed installation 4x cable Ø 

Cable structure: 
• Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5, HD 383 
• Core insulation of halogen-free, cross-linked EI8 to DIN VDE 0207-363-5/DIN EN 50363-5 
• Core identification to DIN VDE 0293-308 
• Cores stranded in layers with optimal lay-length 
• Outer sheath of halogen-free, cross-linked EM8 to DIN VDE 0207-363-6/DIN EN 50363-6  
• Sheath colour black 

Properties: 
• Behaviour in fire to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 and IEC 60332-3-24 
• Corrosiveness of combustion gases acc. to EN 50267-2-2 
• Smoke density to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2 
• Ozone resistant of single core the insulation to DIN VDE 0473-811-403/DIN EN 60811-403 

Note: 
• G = with green-yellow conductor x = without green-yellow conductor 
• AWG sizes are approximate equivalent values. The actual cross-section is in mm². 

Application: 
• Single and multicore sheathed cable, with low smoke and corrosive gas production in case of fire for interior use. Not suitable for continuous outside use. In this case, cable with a special tested covering should be used. Skin contact should be avoided when the cable is used in high temperatures. = The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

technical specification:
awg-no. 14
no.cores x cross-sec. mm² 3 G 2,5
outer ø min. - max. app. mm 10,9 - 14,0
cop. weight kg/km 72,0
weight app. kg/km 211,0
helukabel part number 37204