Belden 9156 Cable 18 AWG 2 Pairs UnShielded Audio Control and Instrumentation Stranded 16x30 TC Multi Conductor Cable

Belden 9156 Cable 18 AWG 2 Pairs UnShielded Audio Control and Instrumentation Stranded 16x30 TC Multi Conductor Cable

Min Length: 30 FT

Select gauge from drop-down menu for prices:

Belden 9156 Cable 18 AWG 2 Pairs UnShielded Audio Control and Instrumentation Stranded 16x30 TC Multi Conductor Cable

Regular price $4.25 $2.83 Sale /per Foot

Belden 9156 Cable 18 AWG 2 Pairs UnShielded Audio Control and Instrumentation Stranded 16x30 TC Multi Conductor Cable

Description:
• 18 AWG stranded (16x30) tinned copper conductors, PVC insulation, twisted pairs, PVC jacket.

Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0330

Inner Shield:
• Material: Unshielded

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.889

Pair Lay Length and Direction:
• Lay Length (in.): 2.000
• Twists (twist/ft): 6.000 (Left Hand Direction)

Mechanical Charactertistics (Overall):
• Operating Temperature Range: -20°C To +80°C
• Bulk Cable Weight: 48 lbs/1000 ft.
• Max. Recommended Pulling Tension: 90 lbs.
• Min. Bend Radius/Minor Axis: 3.500 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMG
• NEC Articles: 800
• CEC/C(UL) Specification: CMG
• AWM Specification: UL Style 2464 (300 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Capacitance Conductor to Conductor (pF/ft): 25.5
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 5.86
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 3.9 Amps/Conductor @ 20°C ambient (10C Temp. Rise)

Flame Test:
• UL Flame Test: UL1685 FT4 Loading
• CSA Flame Test: FT4

Suitability:
• Suitability - Indoor: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): No

technical specification:
awg 18
# pairs 2
stranding 16x30
no. of conductors 4
conductor material tinned copper
outer shield - material unshielded
overall cable- nominal dia. (mm) 8.458
belden cable part number 9156

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question