Belden 7915A Cable 18 AWG 1 Coax RG-6 General Solid BC Duobond Plus Cable

Belden 7915A Cable 18 AWG 1 Coax RG-6 General Solid BC Duobond Plus Cable

Select gauge from drop-down menu for prices:

Belden 7915A Cable 18 AWG 1 Coax RG-6 General Solid BC Duobond Plus Cable

Regular price $0.54 $0.45 Sale /per Foot

Belden 7915A Cable 18 AWG 1 Coax RG-6 General Solid BC Duobond Plus Cable

Description:
• 18 AWG solid .040" bare copper conductor, gas-injected foam polyethylene insulation, Duobond® + aluminum braid shield (77% coverage), PVC jacket.

Insulation:
• Material: Gas-injected FPE - Foam Polyethylene
• Dia. (in.): 0.180

Outer Jacket:
• Material: PVC - Polyvinyl Chloride

Mechnical Characteristics (Overall):
• Operating Temperature Range: -40°C To +80°C
• Non-UL Temperature Rating: 80°C
• Bulk Cable Weight: 32 lbs/1000 ft.
• Max. Recommended Pulling Tension: 91 lbs.
• Min. Bend Radius/Minor Axis: 2.750 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards & Environmental Programs:
• NEC/(UL) Specification: CATV, CM
• CEC/C(UL) Specification: CM
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire & Cable): Yes
• MII Order #39 (China RoHS): Yes
• Series Type: Series 6

Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 75.000
• Nom. Inductance (μH/ft): 0.097
• Nom. Capacitance Conductor to Shield (pF/ft): 16.2
• Nominal Velocity of Propagation VP (%): 83
• Nominal Delay (ns/ft): 1.2
• Nom. Conductor DCR @ 20°C (Ohm/1000 ft): 6.4
• Nom. Outer Shield DCR @ 20°C (Ohm/1000 ft): 4.6
• Max.Operating Voltage - UL: 350 V RMS
• Sweep Testing: 5 MHz - 3 GHz

Flame Test:
• UL Flame Test: UL1685 UL Loading

Plenum/Non-Plenum:
• Plenum (Y/N): No

Benefits:
• All cables rated to 1 GHz
• Crush resistant dielectric material
• Corrosion resistant center conductor

Features:
• Shield options: dual shield (60% braid), tri-shield (77%), or quad shield (60%/40%)
• Indoor (CM, CMR, CMP), messengered and burial versions
• Meets or exceeds applicable ANSI/SCTE standards for drop coaxial cable

technical specification
awg 18
# coax 1
stranding solid
number of conductors 1
conductor material Bare Copper
dia.(in.) 0.040
outer shield - type Tape
outer shield - material Bonded Aluminum Foil-Polyester Tape-Aluminum Foil
oveall cable - nominal dia.(in.) 0.275
belden cable part number 7915A

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question