HW107 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield THHN or THWN Insulation PVC Jacket Copper Conductors - 14 AWG - 8 Pairs

HW107 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield THHN or THWN Insulation PVC Jacket Copper Conductors - 14 AWG - 8 Pairs

HW107 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield THHN or THWN Insulation PVC Jacket Copper Conductors - 14 AWG - 8 Pairs
Technical Specifications:
Catalog Number HW107 01408
Size AWG 14
No. of Pairs
8
PVC Insulation Thickness Mils 15
Nylon Jacket Thickness Mils 4
Overall Jacket Thickness Mils
60
Overall Diameter Inch 0.93
Net Weight Lbs/Mft
520

Specifications:

  • HW106
  • Instrumentation Cable
  • 600 Volt UL Type TC, 90°C
  • Multiple Pairs
  • Individual and Overall Shield
  • TFN Insulation
  • PVC Jacket
  • Copper Conductors

Application:
For use in instrumentation and process control applications where protection from electrostatic interference is required. UL listed as Type PLTC and ITC and approved for installation indoors or outdoors, aerially, in conduits, ducts and cable trays in circuits not exceeding 600 volts. May be used in NEC Class 1, Division 2 hazardous locations.

Conductors:
7-strand soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.

Insulation:
Flame-retardant PVC per UL Standard 62 for Type TFN wire.

Insulation Jacket:
Clear nylon per UL Standard 62 for Type TFN wire.

Individual Shield:
Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.

Overall Shield:
Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire. Jacket: Sunlight-resistant PVC per UL Standard 1277. A ripcord is applied longitudinally under the jacket to facilitate stripping.

Flame Tests:
UL 1581 70,000 BTU/hr flame test

Color Code:

  • ICEA Method 9: black and white pairs with printed number
  • Available upon request: black and red pairs with printed number

Additional Standards:

  • NEC Type TC for Class I Division 2 areas per Articles 336, 392 and 501, and for Class 1 circuits per NEC Article 725
  • NEC Type NPFL for Non Power Limited Fire Protective Signaling circuits per NEC Article 760

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question