Helukabel 26 AWG 30 Pairs PAAR-TRONIC-CY Flexible Cu-Screened Colour Coded To DIN 47100 EMC-Preferred Type Meter Marking Cable 21022

Helukabel 26 AWG 30 Pairs PAAR-TRONIC-CY Flexible Cu-Screened Colour Coded To DIN 47100 EMC-Preferred Type Meter Marking Cable 21022

Select gauge from drop-down menu for prices:

Helukabel 26 AWG 30 Pairs PAAR-TRONIC-CY Flexible Cu-Screened Colour Coded To DIN 47100 EMC-Preferred Type Meter Marking Cable 21022
Helukabel 26 AWG 30 Pairs PAAR-TRONIC-CY Flexible Cu-Screened Colour Coded To DIN 47100 EMC-Preferred Type Meter Marking Cable 21022

Technical data: 
• Special PVC data cables for electronic control adapted to DIN VDE 0812 and 0814 

Temperature range: 
• Flexing -5°C to +80°C 
• Fixed installation -30°C to +80°C 

Operating peak voltage: 
• Not for heavy current installation purposes 350 V 

Test voltage: 
• Core/core 1200 V 
• Core/screen 800 V 

Breakdown voltage: 
• Min. 2400 V 

Insulation resistance: 
• Min. 20 MOhm x km 

Plant capacity:  
• Approx.-value at 800 Hz 
• Core/core 0,14 mm² = 120 pF/m 
• Core/core 0,25 mm² = 150 pF/m 
• Core/screen 0,14 mm² = 240 pF/m 
• Core/screen 0,25 mm² = 270 pF/m 

Inductance: 
• Approx. 0,65 mH/km 

Impedance: 
• Approx. 78 Ohm 

K1-coupling: 
• Approx. 300 pF/100 m 

Coupling resistance: 
• Max.250 Ohm/km 

Minimum bending radius: 
• Flexing 10x cable Ø 
• Fixed installation 5x cable Ø 

Radiation resistance
• Up to 80x106 cJ/kg (up to 80 Mrad) 

Cable structure: 
• Bare copper conductor, from 0,5 mm² to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 
• Conductor construction: 0,14 mm² = 18x0,1, mm 0,25 mm² = 14x0,15 mm, 0,34 mm² = 7x0,25 mm 
• Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 / DIN EN 50363-3 
• Core identification (pair) to DIN 47100 
• Cores stranded in pairs with optimal lay length 
• Pairs stranded in layers with Insulation resistance optimal lay length 
• Foil wrapping 
• drain wire, tinned 
• Tinned copper braided screen, approx. 85% coverage 
• Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1/DIN EN 50363-4-1 
• Sheath colour: grey (RAL 7032) Impedance also available in other colours on request 
• With meter marking 

Properties: 
• Extensively oil resistant, oil-/chemical resistance see "Technical Informations" 
• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers 

Tests: 
• PCV self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) 

Note: 
• AWG sizes are approximate equivalent values. The actual cross section is in mm² 
• Unscreened analogue type: PAAR-TRONIC 

Application: 
• These data control cables are used for flexible use with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. PAAR-TRONIC-CY is well suited for use in areas subject to signal interference. The high level of screening reduces substantially the effects of electrical disturbances from parallel running wiring etc. The copper screening is also often used as an "earth". The twisted pairs conform favourable cross-talk attenuation values. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014/35/EU.

technical specification:
awg-no. 26
no.pairs x cross-sec. mm² 30 x 2 x 0,14
outer ø app. mm
14,1
cop. weight kg/km 140,0
weight app. kg/km 270,0
helukabel part number 21022

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question