Belden 9368 18 AWG 2 Pairs 300V PLTC Multi Conductor Cable

Belden 9368 18 AWG 2 Pairs 300V PLTC Multi Conductor Cable

Regular price $8.40 $5.50 Sale /per Foot

Belden 9368 18 AWG 2 Pairs 300V PLTC Multi Conductor Cable

Description:
• 18 AWG pairs stranded (19x30) tinned copper conductors, twisted pairs, PVC insulation, individually shielded (100% coverage), PVC jacket.

Insulation:
• Material: PVC - Polyvinyl Chloride

Inner Shield:
• Trade Name: Beldfoil®
• Type: Tape
• Material: Aluminum Foil-Polyester Tape

Inner Shield Drian Wire AWG:
• AWG: 20
• Stranding: 19x32
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 1.0668
• Outer Jacket Ripcord: Yes

Overall Cabling Lay Length and Direction:
• Direction: Left-hand Lay

Mechanical Charactertistics (Overall):
• Operating Temperature Range: -30°C To +105°C
• UL Temperature Rating: 105°C
• Bulk Cable Weight: 69 lbs/1000 ft.
• Max. Recommended Pulling Tension: 125 lbs.
• Min. Bend Radius/Minor Axis: 3.750 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMG, ITC-ER, PLTC-ER
• CEC/C(UL) Specification: CMG
• AWM Specification: UL Style 2464 (300 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Inductance (?H/ft): 0.18
• Nom. Capacitance Conductor to Shield (pF/ft): 102
• Nom. Capacitance Conductor to Conductor (pF/ft): 57
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 5.96
Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 8.300 Ohm/1000 ft
• Max. Operating Voltage - UL: 300 V RMS (PLTC CMG)
• Max. Operating Voltage - UL: 150 V RMS (ITC)
• Max. Recommended Current: 6.4 Amps/Conductor @ 25°C

Flame Test:
• UL Flame Test: UL1685 FT4 Loading
• C(UL) Flame Test: FT4
• IEEE Flame Test: 1202

Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
• Suitability - Burial: Yes
• Sunlight Resistance: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): No

technical specification:
awg 18
# pairs 2
stranding 19x30
no. of conductors 4
conductor material tinned copper
outer shield - material unshielded
overall cable- nominal dia. (mm) 9.601
belden cable part number 9368