Belden 83321E Cable 18 AWG 2 Conductors MIL-W-16878/4 Type E Multi Conductor Overall Braid Shield Cable

Belden 83321E Cable 18 AWG 2 Conductors MIL-W-16878/4 Type E Multi Conductor Overall Braid Shield Cable

Select gauge from drop-down menu for prices:

Belden 83321E Cable 18 AWG 2 Conductors MIL-W-16878/4 Type E Multi Conductor Overall Braid Shield Cable

Regular price $23.64 $15.76 Sale /per Foot

Belden 83321E Cable 18 AWG 2 Conductors MIL-W-16878/4 Type E Multi Conductor Overall Braid Shield Cable

Description:
• 18 AWG stranded (19x30) silver-plated copper conductors, cabled and color-coded, extruded TFE Teflon® insulation, silver-plated copper braid shield (85% coverage), TFE teflon tape-wrapped jacket.

Insulation:
• Trade Name: Teflon®
• Material: TFE - Tetrafluoroethylene
• Wall Thickness (mm): 0.2794
• Insulation Resistance: 100,000 Megaohms/1000 ft. @ 500 V DC

Outer Jacket:
• Trade Name: Teflon®
• Material: TFE - Tetrafluoroethylene
• Nom. Wall Thickness (mm): 0.2794

Mechanical Charactertistics (Overall):
• Operating Temperature Range: -65°C To +200°C
• Bulk Cable Weight: 27 lbs/1000 ft.
• Max. Recommended Pulling Tension: 79.200 lbs.
• Min. Bend Radius/Minor Axis: 2 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Military Specification: MIL-W-16878/4 (Type E except stranding) (insulated conductors)
• Other Specification: NEMA HP3

Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 40
• Nom. Inductance (μH/ft): 0.103
• Nom. Capacitance Conductor to Conductor (pF/ft): 31
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/ft): 52.8
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 5.52
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 5.3
• Max. Operating Voltage - Non-UL: 600 V RMS
• Max. Recommended Current: 8.1 Amps/Conductor @ 25°C

Plenum/Non-Plenum:
• Plenum (Y/N): No

technical specification:
awg 18
# conductors 2
stranding 19x30
no. of conductors 2
conductor material silver plated copper
outer shield - type braid
outer shield - material silver plated copper
overall cable- nominal dia. (mm) 4.547
belden cable part number 83321E

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.