Belden 7922A Cable 22 AWG 4 Pairs Category 5e DataTuff Twisted Pair Solid UnShielded Multi Conductor Cable

Belden 7922A Cable 22 AWG 4 Pairs Category 5e DataTuff Twisted Pair Solid UnShielded Multi Conductor Cable

Select gauge from drop-down menu for prices:

Belden 7922A Cable 22 AWG 4 Pairs Category 5e DataTuff Twisted Pair Solid UnShielded Multi Conductor Cable

Regular price $2.85 $1.90 Sale /per Foot

Belden 7922A Cable 22 AWG 4 Pairs Category 5e DataTuff Twisted Pair Solid UnShielded Multi Conductor Cable

General Description:
• 22 AWG Bonded-Pairs solid bare copper conductors, polyolefin insulation, industrial grade sunlight- and oil-resistant PVC jacket, ripcord. Sequential marking at two foot intervals.

Insulation:
• Material: Polyolefin
• Wall Thickness (in.): 0.011
• Diameter (in.): 0.048

Outer Jacket:
• Material: Industrial Grade PVC - Polyvinyl Chloride
• Nominal Wall Thickness (in.): 0.043
• Outer Jacket Ripcord: Yes

Usage (Overall):
Applications:
• Industrial Ethernet, Harsh Environments, 350MHz Enhanced Category 5e, Gigabit Ethernet, 100Base TX, 100BaseVG ANYLAN, 155A TM, 622A TM, NTSC/PAL Component or Composite Video, AES/EBU Digital Audio, AES51, RS-422, CMX - Outdoor, PLTC Listed, Approved for Cable Tray Use in Class 1, Division 2, Hazardous Areas and Non-hazardous Areas, Cable Trays, Raceways, Conduit and Supported by Messenger Wires, Approved for Outdoor Usage

Mechanical Characteristics (Overall):
• Storage Temperature Range: -40°C To +80°C
• Installation Temperature Range: -25°C To +75°C
• Operating Temperature Range: -40°C To +75°C
• Bulk Cable Weight: 42 lbs/1000 ft.
• Max. Recommended Pulling Tension: 40 lbs.
• Min. Bend Radius/Minor Axis: 0.300 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMR, CMX-Outdoor, PLTC
• CEC/C(UL) Specification: CMR
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Telecommunication Standards: Category 5e - TIA 568.C.2
• Other Specification: Ethernet I/P, NEMA WC-63.1 Category 5e

Electrical Characteristics (Overall):
• Nom. Mutual Capacitance: (pF/ft): 15
• Maximum Capacitance Unbalance (pF/100 m): 66
• Nominal Velocity of Propagation: VP (%): 70
• Maximum Delay (ns/100 m): 510
• Max. Delay Skew (ns/100 m): 25
• Maximum Conductor DC Resistance @ 20°C (Ohm/100 m): 9
• Max. Operating Voltage - UL: 300 V RMS
• Maximum DCR Unbalanced @ 20°C (%): 3

Flame Test:
• UL Flame Test: UL 1666 Vertical Riser
• CSA Flame Test: FT4
• IEEE Flame Test: 1202

Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
• Sunlight Resistance: Yes
• Oil Resistance: Yes

Plenum/Non-Plenum:
• Plenum(Y/N): No

technical specification:
awg 22
# pairs 4
stranding solid
no. of conductors 8
conductor material bare copper
outer shield - trade name -
outer shield - type -
outer shield- material Unshielded
outer shield - coverage (%) -
overall cable - nominal diameter(in.) 0.301
belden cable part number 7922A

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.