Belden 7804WB Cable 24 AWG and 20 AWG SMPTE Camera 311M HDTV Composite Waterblock Cable

Belden 7804WB Cable 24 AWG and 20 AWG SMPTE Camera 311M HDTV Composite Waterblock Cable

Belden 7804WB Cable 24 AWG and 20 AWG SMPTE Camera 311M HDTV Composite Waterblock Cable

Description:
• Industry Standard SMPTE 311M Cable Waterblocked, 4 power conductors, SM fibers w/24 and 20 AWG stranded (7x32 and 19x32) TC conductors, PVC insulation, TC braid shield (95% coverage), Belflex® jacket.

Insulation:
• Materials: PVC - Polyvinyl Chloride (20 AWG and 24 AWG)
• Diameters (in.): 0.063 (20 AWG) and 0.050 (24 AWG)

Outer Jacket:
• Material: PE - Polyethylene

Strength Member:
• Overall Strength Member Diameter: 0.089
• Material: 302 Stainless Steel

Fiber:
Physical Characteristics:
• Fiber Type: Non-Dispersion Shifted, Single Mode/125/900 Micron
• Number of Fibers: 2
• Mode Field Diameter @ 1310nm: 9.5 +/-1 microns
• Clad Diameter: 125 microns
• Core-clad Concentricity Error: < to 1 micron
• Primary Coating Material: Acrylate
• Buffer Tube Diameter: 900 microns
• Buffer Tube Material: PVC - Polyvinyl Chloride

Optical Characteristics:
• Maximum Attenuation @ 1310nm: 0.8 dB/km

Usage (Overall):
Applications:
• SMPTE 311M Camera Cable

Mechanical Charactertistics (Overall):
• Operating Tempeature Range: -40°C To +75°C
• Bulk Cable Weight: 78 lbs/1000 ft.
• Max. Recommended Pulling Tension: 450 lbs.
• Min. Bend Radius/Minor Axis: 3.500 in.
• Crush Resistance: Compression, FOTP-41: 397 lbs.
• Impact Resistance: FOTP-25: 20 Cycles @ 1.32 lbs.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 08/02/2011
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: SMPTE 311

Electrical Characteristics (Individual Shield):
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 23.300 (24 AWG)
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 8.800 (20 AWG)
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 3.500

Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
• Suitability - Burial: Yes
• Sunlight Resistance: Yes
• Suggested Connectors: SMPTE 304M Connectors

Plenum/Non-Plenum:
• Plenum (Y/N): No

technical specification:
awg 24 and 20
# conductors 2 and 4
stranding 7x32 and 19x32
conductor material tinned copper
dia. (in.) 0.024 and 0.037
outer shield - type braid
outer shield - material tinned copper
overall cable- nominal dia. (in.) 0.362
belden cable part number 7804WB