Description:
• 24 AWG stranded (19x36) HC TC conductors, high-density polyethylene insulation, twisted pair, noise reducing tape, Beldfoil® shield (100% coverage), 24 AWG stranded TC drain wire, PVC jacket.

Insulation:
• Material: HDPE - High Density Polyethylene
• Wall Thickness (in.): 0.008
• Diameter (in.): 0.040

Outer Shield Drain Wire AWG:
• AWG: 24
• Stranding: Stranded
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride

Mechanical Charactertistics (Overall):
• Operating Tempeature Range: -40°C To +75°C
• Non-UL Tempeature Range: 75°C
• Bulk Cable Weight: 11 lbs/1000 ft.
• Max. Recommended Pulling Tension: 17.700 lbs.
• Min. Bend Radius/Minor Axis: 1.500 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 56
• Nom. Inductance (μH/ft): 0.18
• Nom. Capacitance Conductor to Conductor (pF/ft): 30
• Nom. Capacitance Conductor to Conductor and Shield (pF/ft): 58
• Nominal Velocity of Propagation: VP (%): 52
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 25
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 16.5
• Max. Operating Voltage - Non-UL: 200 V RMS
• Max. Recommended Current: 2.2 Amps/Conductor @ 25°C

Plenum/Non-Plenum:
• Plenum (Y/N): No

technical specification:
awg 24
# conductors 2
stranding 19x36
no. of conductors 2
conductor material tinned copper
dia. (in.) 0.024
outer shield - type tape
outer shield - material noise reducing
overall cable- nominal dia. (in.) 0.135
belden cable part number 9452