Belden 8720 Cable 14 AWG 1 Pair Overall Beldfoil Shield Audio Control and Instrumentation Stranded 19x27 PVC Jacket Cable

Belden 8720 Cable 14 AWG 1 Pair Overall Beldfoil Shield Audio Control and Instrumentation Stranded 19x27 PVC Jacket Cable

Regular price $5.39 $3.59 Sale /per Foot

Belden 8720 Cable 14 AWG 1 Pair Overall Beldfoil Shield Audio Control and Instrumentation Stranded 19x27 PVC Jacket Cable

Description:
• 14 AWG stranded (19x27) TC conductors, polyethylene insulation, twisted pair, overall Beldfoil® shield (100% coverage), 16 AWG stranded TC drain wire, PVC jacket.

Insulation:
• Material: PE - Polyethylene
• Wall Thickness (mm): 0.8128

Outer Shield Drain Wire AWG:
• AWG: 16
• Stranding: Stranded
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.889

Mechanical Charactertistics (Overall):
• Operating Temperature Range: -20°C To +80°C
• UL Temperature Rating: 80°C (UL AWM Style 20253)
• Bulk Cable Weight: 95.245 Kg/Km
• Max. Recommended Pulling Tension: 711.712 N
• Min. Bend Radius/Minor Axis: 95.250 mm

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CL2
• AWM Specification: UL Style 20253 (600 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 58
• Nom. Inductance (μH/m): 0.6562
• Nom. Capacitance Conductor to Conductor (pF/m): 78.744
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/m): 154.207
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 9.5149
• Max. Operating Voltage - UL: 600 V RMS (UL AWM 20253)
• Max. Operating Voltage - UL: 300 V RMS (CSA)
• Max. Recommended Current: 9.5 Amps/Conductor @ 25°C

Flame Test:
• UL Flame Test: UL1685 UL Loading

Plenum/Non-Plenum:
• Plenum (Y/N): No

technical specification:
awg 14
# pairs 1
stranding 19x27
no. of conductors 2
conductor material tinned copper
outer shield - type tape
outer shield - material aluminum foil-polyester tape
overall cable- nominal dia. (mm) 9.017
belden cable part number 8720

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.