Belden 8719 Cable 16 AWG 1 Pair Overall Beldfoil Shield Audio Control and Instrumentation Stranded 19x29 PVC Jacket Cable

Belden 8719 Cable 16 AWG 1 Pair Overall Beldfoil Shield Audio Control and Instrumentation Stranded 19x29 PVC Jacket Cable

Regular price $3.93 $2.62 Sale /per Foot

Belden 8719 Cable 16 AWG 1 Pair Overall Beldfoil Shield Audio Control and Instrumentation Stranded 19x29 PVC Jacket Cable

Description:
• 16 AWG stranded (19x29) TC conductors, polyethylene insulation, twisted pair, overall Beldfoil® shield (100% coverage), 18 AWG stranded TC drain wire, PVC jacket.

Insulation:
• Material: PE - Polyethylene
• Wall Thickness (mm): 0.8128

Outer Shield Drain Wire AWG:
• AWG: 18
• Stranding: Stranded
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.8128

Pair Lay Length and Direction:
• Lay Length (in.): 2.750
• Twists (twist/ft): 4.400 (Left Hand Direction)

Mechanical Charactertistics (Overall):
• Operating Temperature Range: -20°C To +80°C
• UL Temperature Rating: 80°C (UL AWM Style 20253)
• Bulk Cable Weight: 44 lbs/1000 ft.
• Max. Recommended Pulling Tension: 102 lbs.
• Min. Bend Radius/Minor Axis: 3.250 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CL2, CM
• NEC Articles: 800, 725
• CEC/C(UL) Specification: CM
• AWM Specification: UL Style 20253 (600 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 65
• Nom. Inductance (μH/ft): 0.2
• Nom. Capacitance Conductor to Conductor (pF/ft): 23
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/ft): 44
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 4.5
• Max. Operating Voltage - UL: 600 V RMS (UL AWM Style 20253)
• Max. Operating Voltage - UL: 300 V RMS (UL type CM)
• Max. Operating Voltage - UL: 150 V RMS (UL type CL2)
• Max. Recommended Current: 7 Amps/Conductor @ 25°C ambient (10C Temp. Rise)

Flame Test:
• UL Flame Test: UL1685 UL Loading
• CSA Flame Test: FT1

Suitability:
• Suitability - Indoor: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): No

technical specification:
awg 16
# pairs 1
stranding 19x29
no. of conductors 2
conductor material tinned copper
outer shield - type tape
outer shield - material aluminum foil-polyester tape w/shorting fold
overall cable- nominal dia. (mm) 7.950
belden cable part number 8719

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question