Prysmian Cable 250 MCM AL 600 Volt USEI90 Low Voltage Utility Cables Q0ULSYC
Select gauge from drop-down menu for prices:
- Prysmian Cable 600 Volt USEI90 Low Voltage Utility Cables
- Prysmian Cable 2/0 AWG AL 600 Volt USEI90 Low Voltage Utility Cables Q0RLR0C
- Prysmian Cable 3/0 AWG AL 600 Volt USEI90 Low Voltage Utility Cables Q0SLQYC
- Prysmian Cable 3/0 AWG AL 600 Volt USEI90 Low Voltage Utility Cables Q0SLS0C
- Prysmian Cable 4/0 AWG AL 600 Volt USEI90 Low Voltage Utility Cables Q0TLRYC
- Prysmian Cable 4/0 AWG AL 600 Volt USEI90 Low Voltage Utility Cables Q0TLT0C
- Prysmian Cable 250 MCM AL 600 Volt USEI90 Low Voltage Utility Cables Q0ULU0C
- Prysmian Cable 350 MCM AL 600 Volt USEI90 Low Voltage Utility Cables Q0VLUYC
- Prysmian Cable 350 MCM AL 600 Volt USEI90 Low Voltage Utility Cables Q0VLV0C
- Prysmian Cable 500 MCM AL 600 Volt USEI90 Low Voltage Utility Cables Q0WLVYC
- Prysmian Cable 500 MCM AL 600 Volt USEI90 Low Voltage Utility Cables Q0WLW0C
Conductor: Multiple, Class B Compact, aluminum alloy 1350 per ASTM.
Insulation: High dielectric strength low temperature cross-linked polyethylene (XLPE) insulation, exhibiting an optimum balance of mechanical and electrical properties to assure extended cable life.
Jacket: Low-temperature appropriately colored polyvinyl chloride (PVC) jacket is extruded over each individual cable.
Assembly: Full or reduced neutral conductor, insulated and jacketed, class compact concentric strand aluminum alloy 1350 per ASTM, twisted together with the phase conductors.
Description: A twisted assembly, consisting of multiple aluminum phase conductors and one neutral conductor, each insulated with a low temperature, moisture resistant cross-linked polyethylene (XLPE) insulation that is formulated for a balance of flexibility and mechanical toughness, and a PVC jacket.
Options:
• Colored jacket
• Copper or ACM conductors
• Polyethylene-insulated USEI 75
Installation:
• Conduit in Air
• Direct Buried
• Underground Duct
• Wet Locations
• Dry Locations
• Utility Secondary
• Industrial
Specifications and Ratings:
• CSA- CSA C22.2 No. 52 -40oC
• FT1
• Sunlight Resistant
• For 90°C wet or dry operation.
technical specifications: | |
phase conductors | 2-1/c 250 MCM al |
neutral conductor | 3/0 awg al |
insulation thickness (mils) - phase | 65 |
insulation thickness (mils) - neutral | 55 |
jacket thickness (mils) - phase | 65 |
jacket thickness (mils) - neutral | 45 |
approximate diameter (mm) - phase (a) | 20.32 |
approximate diameter (mm) - neutral (b) | 16.15 |
approximate diameter (mm) - overall (c) | 43.94 |
cable weight (kg/km) | 1488 |
† ampacity (amps) | 230 |
prysmian cable part number | Q0ULSYC |