Prysmian and Draka Cable 16 AWG 6TSP Conductors INDUSTRITE C-FLEX Control For shipyard crane and festoon systems 90C to -40C 600V Cable 030856

Prysmian and Draka Cable 16 AWG 6TSP Conductors INDUSTRITE C-FLEX Control For shipyard crane and festoon systems 90C to -40C 600V Cable 030856

Select gauge from drop-down menu for prices:

Prysmian and Draka Cable 16 AWG 6TSP Conductors INDUSTRITE C-FLEX Control For shipyard crane and festoon systems 90C to -40C 600V Cable 030856

Product Details

Conductors: Extra-flexible rope stranding (Class K), soft-drawn copper per ASTM B-3, ASTM B-172, and UL-62 offers high flexibility, extended flex-life and reduced copper fatigue/conductor breakage.

Separator: Paper separator for easy stripping. 

Insulation: Thermoset (EPDM) insulation per UL-62 and ANSI/NEMA WC70 ICEA S-95-658 with excellent physical and electrical properties and stability during extreme flexing/twisting.

Cabling: Conductors are cabled with nonhygroscopic fillers, without a separator which allows pressure-extruded jacket to fill interstices and prohibits conductor displacement during flexing operations. Control cables use a binder tape.

Jacket: Black, oil and flame resistant two layer thermoset jacket per UL-62 and ANSI/NEMA WC70 ICEA S-95-658, suitable for use indoors and outdoors in continuous flexing applications where exposure to moisture, temperature, sunlight and mechanical abuse are considerations.

Applications:
•INDUSTRITE™ C-FLEX cables are designed and manufactured for use in festoon systems functioning on gantry cranes or other material handling equipment.
•C-Flex cables are typically used in applications requiring frequent flexing and mechanical stress. C-Flex is recommended for festoon systems operating at travel speeds up to 200 meters per minute. Consult Draka for speeds greater than 200 m/min based on system design.

Specifications and Ratings:
• Rated for continuous operation. at 90° C to -40° C .
• UL festooning 

Construction Options:
Consult factory for INDUSTRITE™ C-FLEX Cables designed and manufactured in a variety of alternative constructions for specific applications.

Options include: 
• Overall shields 
• composite conductors
• Fiber optic components

technical specification:
conductor size 16 (1.5)
stranding 26/30
conductor number 6tsp
nominal insulation thickness in (mm) 0.030 (0.76)
nominal jacket thickness in (mm) 0.155 (3.94)
nominal cable o.d. in (mm) 1.170 (29.7)
ampacity1 13
minimum bend diameter in (mm) 14.0 (356.6)
approximate cable weight lbs/mft (kg/km) 662 (986)
prysmian and draka cable Part Number 030856